YN018GMFI22RPE
YN series · YN-series
6 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YN018GMFI22RPE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 6 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 20–23 | 6 / 6 |
| EER2 · BTU/Wh | 12.5 | 6 / 6 |
| HSPF2 · BTU/Wh | 10–10.7 | 6 / 6 |
| Cooling capacity · BTU/h | 16,000–18,000 | 6 / 6 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 17,000–20,000 | 6 / 6 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 12,000–13,400 | 6 / 6 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,700–13,100 | 6 / 6 |
| COP at 5°F / −15°C | 2.08–2.4 | 6 / 6 |
| Equipment / loop type | HP - Mini or Multi Split | 6 / 6 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 6 / 6 |
| Compressor staging | Continuously variable | 6 / 6 |
| Connected capability | No | 6 / 6 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
UB018GMFILCFHDAHRI reference: 208141956 | 23.00 | 10.00 | 13000 | 2.08 | EPA 2473787 → |
UB018GMFILCFHDAHRI reference: 208141956 | 23.00 | 10.00 | 13000 | 2.08 | EPA 2473811 → |
FB018GMFILDFHECold climate designationAHRI reference: 213349747 | 22.40 | 10.40 | 12700 | 2.32 | EPA 2740181 → |
CK018GMFILCFHDAHRI reference: 213349744 | 21.80 | 10.70 | 13100 | 2.30 | EPA 2740178 → |
CB018GMFILCFHDAHRI reference: 208191863 | 20.50 | 10.50 | 12700 | 2.16 | EPA 2473862 → |
RB018GMFILDFHDAHRI reference: 208141953 | 20.00 | 10.60 | 13000 | 2.40 | EPA 2473793 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.