PAYNE HEATING AND COOLING / AIR-SOURCE HEAT PUMP

PH8TAN560**AA*

2-STAGE 18 SEER HP

48 published source records · source checked Sep 21, 2026

SEER2 range16–17.5BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN560**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 48 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–17.548 / 48
EER2 · BTU/Wh11.7–1348 / 48
HSPF2 · BTU/Wh8–8.548 / 48
Cooling capacity · BTU/h54,000–57,50048 / 48
Heating capacity at 47°F / 8.3°C · BTU/h56,500–60,00048 / 48
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50048 / 48
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80048 / 48
COP at 5°F / −15°C2.12–2.3448 / 48
Equipment / loop typeHP - Split System48 / 48
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)48 / 48
Compressor stagingTwo-stage48 / 48
Connected capabilityNo48 / 48

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
PF5TNBD60L*AHRI reference: 21556074217.508.10302002.30EPA 3982829 →
CAA**6024AM*+ furnace: PG80MSUA60080C**AHRI reference: 21562909016.508.00296002.30EPA 3951004 →
CAA**6124AM*+ furnace: PG80MSUA60080C**AHRI reference: 21563005016.508.00298002.30EPA 3951411 →
CAA**6124AM*+ furnace: PG80MSUA60100C**AHRI reference: 21563006916.508.00302002.30EPA 3951431 →
CAA**6121AM*+ furnace: PG80MSUA60080C**AHRI reference: 21562961116.508.00298002.30EPA 3951566 →
CAA**6124AM*+ furnace: PG80VTLB66110C**AHRI reference: 21563016016.508.10300002.14EPA 3951666 →
CAA**6124AM*+ furnace: PG80VTLB66135D**AHRI reference: 21563017816.508.10300002.14EPA 3951687 →
CAA**6121AM*+ furnace: PG80VTLB66110C**AHRI reference: 21562972116.508.00300002.30EPA 3951792 →
CVAMA6124XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562663516.008.50318002.32EPA 3949851 →
CVAMA6124XMA*+ furnace: PG80VTLB66135D**AHRI reference: 21562666916.008.50314002.34EPA 3949865 →
CVAVA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562701516.008.10306002.22EPA 3949916 →
CVAVA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562703416.008.10304002.22EPA 3949935 →
CVAVA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562705316.008.10304002.22EPA 3949950 →
CVAVA6021XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562711416.008.10304002.20EPA 3950069 →
CVAVA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562713016.008.10304002.22EPA 3950087 →
CVAMA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562582416.008.10300002.22EPA 3950190 →
CVAMA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562584316.008.10298002.24EPA 3950209 →
CVAMA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562586216.008.10304002.24EPA 3950229 →
CVAMA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562595316.008.10300002.24EPA 3950275 →
CVAMA6021XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562610516.008.10302002.22EPA 3950306 →