PH8TAN560**AA*
2-STAGE 18 SEER HP
48 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH8TAN560**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 48 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17.5 | 48 / 48 |
| EER2 · BTU/Wh | 11.7–13 | 48 / 48 |
| HSPF2 · BTU/Wh | 8–8.5 | 48 / 48 |
| Cooling capacity · BTU/h | 54,000–57,500 | 48 / 48 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–60,000 | 48 / 48 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,200–38,500 | 48 / 48 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,600–31,800 | 48 / 48 |
| COP at 5°F / −15°C | 2.12–2.34 | 48 / 48 |
| Equipment / loop type | HP - Split System | 48 / 48 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 48 / 48 |
| Compressor staging | Two-stage | 48 / 48 |
| Connected capability | No | 48 / 48 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
PF5TNBD60L*AHRI reference: 215560742 | 17.50 | 8.10 | 30200 | 2.30 | EPA 3982829 → |
CAA**6024AM*+ furnace: PG80MSUA60080C**AHRI reference: 215629090 | 16.50 | 8.00 | 29600 | 2.30 | EPA 3951004 → |
CAA**6124AM*+ furnace: PG80MSUA60080C**AHRI reference: 215630050 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951411 → |
CAA**6124AM*+ furnace: PG80MSUA60100C**AHRI reference: 215630069 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951431 → |
CAA**6121AM*+ furnace: PG80MSUA60080C**AHRI reference: 215629611 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951566 → |
CAA**6124AM*+ furnace: PG80VTLB66110C**AHRI reference: 215630160 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951666 → |
CAA**6124AM*+ furnace: PG80VTLB66135D**AHRI reference: 215630178 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951687 → |
CAA**6121AM*+ furnace: PG80VTLB66110C**AHRI reference: 215629721 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951792 → |
CVAMA6124XMA*+ furnace: PG80VTLB60090C**AHRI reference: 215626635 | 16.00 | 8.50 | 31800 | 2.32 | EPA 3949851 → |
CVAMA6124XMA*+ furnace: PG80VTLB66135D**AHRI reference: 215626669 | 16.00 | 8.50 | 31400 | 2.34 | EPA 3949865 → |
CVAVA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 215627015 | 16.00 | 8.10 | 30600 | 2.22 | EPA 3949916 → |
CVAVA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215627034 | 16.00 | 8.10 | 30400 | 2.22 | EPA 3949935 → |
CVAVA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 215627053 | 16.00 | 8.10 | 30400 | 2.22 | EPA 3949950 → |
CVAVA6021XMA*+ furnace: PG80VTLB60090C**AHRI reference: 215627114 | 16.00 | 8.10 | 30400 | 2.20 | EPA 3950069 → |
CVAVA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 215627130 | 16.00 | 8.10 | 30400 | 2.22 | EPA 3950087 → |
CVAMA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 215625824 | 16.00 | 8.10 | 30000 | 2.22 | EPA 3950190 → |
CVAMA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215625843 | 16.00 | 8.10 | 29800 | 2.24 | EPA 3950209 → |
CVAMA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 215625862 | 16.00 | 8.10 | 30400 | 2.24 | EPA 3950229 → |
CVAMA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 215625953 | 16.00 | 8.10 | 30000 | 2.24 | EPA 3950275 → |
CVAMA6021XMA*+ furnace: PG95MSUA60100C**AHRI reference: 215626105 | 16.00 | 8.10 | 30200 | 2.22 | EPA 3950306 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.