Heating performance & equipment details
Ranges include the 202 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 202 / 202 |
| EER2 · BTU/Wh | 11.5–14 | 202 / 202 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 202 / 202 |
| Cooling capacity · BTU/h | 22,200–25,000 | 202 / 202 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–25,200 | 202 / 202 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,100–14,900 | 202 / 202 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,700–11,400 | 202 / 202 |
| COP at 5°F / −15°C | 1.9–2.24 | 202 / 202 |
| Equipment / loop type | HP - Split System | 202 / 202 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 202 / 202 |
| Compressor staging | Two-stage | 202 / 202 |
| Connected capability | No | 202 / 202 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*2412AM*+ furnace: PG80VTLB48090B**AHRI reference: 215649323 | 16.00 | 8.00 | 11100 | 2.05 | EPA 3997136 → |
CSAH*2412AM*+ furnace: PG95MSUA36040B**AHRI reference: 215649738 | 16.00 | 7.80 | 11200 | 2.00 | EPA 3997189 → |
CSAH*2412AM*+ furnace: PG96VTAB60080C**AHRI reference: 215650125 | 16.00 | 8.00 | 11100 | 2.05 | EPA 3997223 → |
CSAH*2412AM*+ furnace: PG97VTAA66120D**AHRI reference: 215713071 | 16.00 | 8.00 | 11100 | 2.05 | EPA 3997320 → |
CSAH*2412AM*+ furnace: PG97VTAA60080C**AHRI reference: 215713023 | 16.00 | 8.00 | 11100 | 2.05 | EPA 3997347 → |
CSAH*3012AM*+ furnace: PG96VTAB30040A**AHRI reference: 215651458 | 16.00 | 8.00 | 11400 | 2.05 | EPA 3997420 → |
CSAH*2412AM*+ furnace: PG80MSUA36040B**AHRI reference: 215648980 | 16.00 | 7.80 | 11000 | 2.05 | EPA 3997438 → |
CSAH*3012AM*+ furnace: PG95MSUA36040B**AHRI reference: 215651195 | 16.00 | 8.00 | 11100 | 2.05 | EPA 3997598 → |
CAA**3617AM*+ furnace: PG97VTAA30040A**AHRI reference: 217991754 | 16.00 | 8.00 | 11200 | 2.02 | EPA 4566331 → |
CAA**2417AM*+ furnace: PG97VTAA36060A**AHRI reference: 217991364 | 16.00 | 8.00 | 11100 | 2.04 | EPA 4566470 → |
CAA**2417AM*+ furnace: PG97VTAA36040B**AHRI reference: 217991508 | 16.00 | 8.00 | 11300 | 2.00 | EPA 4566535 → |
CAA**2517AM*+TDRAHRI reference: 215643085 | 15.50 | 7.80 | 11100 | 1.96 | EPA 3956920 → |
CAA**3721AM*+TDRAHRI reference: 215643223 | 15.50 | 7.80 | 11100 | 1.94 | EPA 3956941 → |
CAA**2414AM*+ furnace: PG96VTAB30040A**AHRI reference: 215643529 | 15.50 | 8.10 | 11200 | 2.02 | EPA 3957058 → |
CAA**2417AM*+ furnace: PG96VTAB30040A**AHRI reference: 215644174 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3957637 → |
CSAH*3012AM*+ furnace: PG97VTAA48060B**AHRI reference: 215721083 | 15.50 | 7.80 | 11100 | 2.06 | EPA 3981045 → |
CSAH*3012AM*+ furnace: PG97VTAA60080C**AHRI reference: 215721119 | 15.50 | 7.80 | 11100 | 2.06 | EPA 3981084 → |
CSAH*3012AM*+ furnace: PG97VTAA60100C**AHRI reference: 215721135 | 15.50 | 7.80 | 11000 | 2.08 | EPA 3981946 → |
CAA**2414AM*+ furnace: PG97VTAA30040A**AHRI reference: 217991654 | 15.50 | 8.00 | 11200 | 2.02 | EPA 4566601 → |
CAA**2417AM*+ furnace: PG97VTAA30040A**AHRI reference: 217991674 | 15.50 | 8.00 | 11300 | 1.98 | EPA 4566621 → |