PH5SAN536**AA*
15 SEER2 HP
22 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH5SAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 22 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 22 / 22 |
| EER2 · BTU/Wh | 12–13 | 22 / 22 |
| HSPF2 · BTU/Wh | 7.8–8 | 22 / 22 |
| Cooling capacity · BTU/h | 33,800–36,800 | 22 / 22 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,400 | 22 / 22 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 22 / 22 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,100 | 22 / 22 |
| COP at 5°F / −15°C | 2–2.22 | 22 / 22 |
| Equipment / loop type | HP - Split System | 22 / 22 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 22 / 22 |
| Compressor staging | Single stage | 22 / 22 |
| Connected capability | No | 22 / 22 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 217051638 | 16.00 | 8.00 | 17400 | 2.18 | EPA 4001107 → |
PF5TNXC48L*AHRI reference: 214179938 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404461 → |
FJ5AN*C48L*AHRI reference: 214180179 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3404795 → |
PF5MN*C48L*AHRI reference: 214180180 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3404797 → |
FEVB0048**+NAVA54801CKAHRI reference: 214277599 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3415687 → |
FMA5X36**AL*AHRI reference: 214424290 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425179 → |
CAA**4321AM*+ furnace: PG80MS(A,L)A60110C**AHRI reference: 214139976 | 15.20 | 7.80 | 18000 | 2.20 | EPA 3400440 → |
CAA**4821AM*+ furnace: PG80VTLB60090C**AHRI reference: 214141945 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400610 → |
CAA**4821AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214141340 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400766 → |
CAA**4321AM*+ furnace: PG92MSAA60100C**AHRI reference: 214140513 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400789 → |
CAA**4821AM*+ furnace: PG80MS(A,L)A60110C**AHRI reference: 214141370 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3400838 → |
CAA**4821AM*+ furnace: PG92MSAA60100C**AHRI reference: 214142259 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400871 → |
CVAMA4421XMA*+ furnace: PG80ESUA36040B**AHRI reference: 214143048 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401012 → |
CAA**3721AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214138230 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3401143 → |
CAA**4821AM*+ furnace: PG80MSUA48060B**AHRI reference: 214141632 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3401218 → |
CAA**4821AM*+ furnace: PG80MSUA60080C**AHRI reference: 214141664 | 15.20 | 7.80 | 17300 | 2.20 | EPA 3401261 → |
CAA**4321AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214139946 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3401308 → |
CVAVA4224XMA*+ furnace: PG80MSUA60100C**AHRI reference: 214144593 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401864 → |
FJ5AN*C42L*AHRI reference: 214179895 | 15.20 | 7.80 | 16100 | 2.02 | EPA 3404665 → |
PF5MN*C42L*AHRI reference: 214179896 | 15.20 | 7.80 | 16100 | 2.02 | EPA 3404667 → |