PAYNE HEATING AND COOLING / AIR-SOURCE HEAT PUMP

PH5SAN524**AA*

15 SEER2 HP · source records, page 6

118 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for PH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 118 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5118 / 118
EER2 · BTU/Wh11.7–13118 / 118
HSPF2 · BTU/Wh7.8–8.5118 / 118
Cooling capacity · BTU/h22,200–24,400118 / 118
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000118 / 118
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200118 / 118
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900118 / 118
COP at 5°F / −15°C1.98–2.26118 / 118
Equipment / loop typeHP - Split System118 / 118
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)118 / 118
Compressor stagingSingle stage118 / 118
Connected capabilityNo118 / 118

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: PG96VTAB48060B**AHRI reference: 21420123015.207.80114002.08EPA 3406619
CAA**3717AM*+ furnace: PG80VTLB48090B**AHRI reference: 21420039315.207.80113002.08EPA 3406698
CAA**3717AM*+ furnace: PG80VTLB36045A**AHRI reference: 21420032315.207.80112002.08EPA 3406725
CAA**3721AM*+ furnace: PG80VTLB48090B**AHRI reference: 21420205015.207.80116002.14EPA 3406768
CAA**3717AM*+ furnace: PG80MS(A,L)A36045A**AHRI reference: 21419969815.207.80113002.08EPA 3407177
CAA**3721AM*+ furnace: PG96VTAB48060B**AHRI reference: 21420316215.207.80118002.12EPA 3407443
CAA**3721AM*+ furnace: PG96VTAB48080B**AHRI reference: 21420319315.207.80116002.12EPA 3407473
CAA**3717AM*+ furnace: PG92MSAA36060A**AHRI reference: 21420066315.207.80113002.08EPA 3407567
CAA**3717AM*+ furnace: PG96MSAA48060B**AHRI reference: 21420078715.207.80114002.08EPA 3407619
CAA**3721AM*+ furnace: PG96MSAA48060B**AHRI reference: 21420247615.207.80117002.12EPA 3407948
CAA**3721AM*+ furnace: PG96MSAA48080B**AHRI reference: 21420250815.207.80116002.12EPA 3407984
CAA**2517AM*+ furnace: PG80MS(A,L)A36070A**AHRI reference: 21421034715.207.80113002.12EPA 3409737
CAA**2517AM*+ furnace: PG80ESUA36040B**AHRI reference: 21421046615.207.80110002.08EPA 3410360
CAA**2517AM*+ furnace: PG80VTLB36045A**AHRI reference: 21421068815.207.80113002.12EPA 3410934
CAA**2517AM*+ furnace: PG92MSAA48080B**AHRI reference: 21421079415.207.80114002.12EPA 3410995
CAA**2517AM*+ furnace: PG80VTLB36070A**AHRI reference: 21421071815.207.80113002.12EPA 3411015
FMA5L30**AL*AHRI reference: 21442401015.208.10119002.16EPA 3425292
FM(C,U)5S24**AL*AHRI reference: 21845224715.207.80111002.00EPA 4624517