37MUHAQ30AA3+KSAIC0701230
Crossover Heat Pump · source records, page 12
244 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ30AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 244 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 244 / 244 |
| EER2 · BTU/Wh | 9.5–10.5 | 244 / 244 |
| HSPF2 · BTU/Wh | 8.1–9 | 244 / 244 |
| Cooling capacity · BTU/h | 28,600–31,200 | 244 / 244 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 244 / 244 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,400 | 244 / 244 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 244 / 244 |
| COP at 5°F / −15°C | 1.75–1.98 | 244 / 244 |
| Equipment / loop type | HP - Split System | 244 / 244 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 244 / 244 |
| Compressor staging | Continuously variable | 244 / 244 |
| Connected capability | No | 244 / 244 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*4212AM*+ furnace: PG96VTAB48060B**Cold climate designationAHRI reference: 218477679 | 15.20 | 8.50 | 32600 | 1.82 | EPA 4627610 → |
CSAH*4212AM*+ furnace: PG95MSUA60100C**Cold climate designationAHRI reference: 218477657 | 15.20 | 8.50 | 32600 | 1.82 | EPA 4627614 → |
CSAH*4212AM*+ furnace: PG95MSUA60080C**Cold climate designationAHRI reference: 218477653 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627616 → |
CSAH*4212AM*+ furnace: PG95MSUA48060B**Cold climate designationAHRI reference: 218477649 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627618 → |
CSAH*4212AM*+ furnace: PG95MSUA36040B**Cold climate designationAHRI reference: 218477646 | 15.20 | 8.50 | 32600 | 1.84 | EPA 4627620 → |
CSAH*4212AM*+ furnace: PG96MSAA60100C**Cold climate designationAHRI reference: 218477618 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627628 → |
CSAH*4212AM*+ furnace: PG92MSAA60100C**Cold climate designationAHRI reference: 218477589 | 15.20 | 8.50 | 32400 | 1.84 | EPA 4627631 → |
CSAH*4212AM*+ furnace: PG92MSAA60080C**Cold climate designationAHRI reference: 218477585 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627633 → |
CSAH*4212AM*+ furnace: PG92MSAA48080B**Cold climate designationAHRI reference: 218477581 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627635 → |
CSAH*4212AM*+ furnace: PG80VTLB66135D**Cold climate designationAHRI reference: 218477569 | 15.20 | 8.50 | 32600 | 1.82 | EPA 4627637 → |
CSAH*4212AM*+ furnace: PG80MSUA60100C**Cold climate designationAHRI reference: 218477542 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627651 → |
CSAH*4212AM*+ furnace: PG80MSUA48060B**Cold climate designationAHRI reference: 218477534 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627655 → |
CSAH*4212AM*+ furnace: PG80MSUA36040B**Cold climate designationAHRI reference: 218477530 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627657 → |
CSAH*4212AM*+ furnace: PG80MS(A,L)A60155D**Cold climate designationAHRI reference: 218477513 | 15.20 | 8.50 | 32600 | 1.82 | EPA 4627666 → |
CSAH*4212AM*+ furnace: PG80MS(A,L)A60135D**Cold climate designationAHRI reference: 218477509 | 15.20 | 8.50 | 32400 | 1.84 | EPA 4627668 → |
CSAH*4212AM*+ furnace: PG80MS(A,L)A60110C**Cold climate designationAHRI reference: 218477501 | 15.20 | 8.50 | 32400 | 1.86 | EPA 4627672 → |
CSAH*4212AM*+ furnace: PG80MS(A,L)A60090C**Cold climate designationAHRI reference: 218477495 | 15.20 | 8.50 | 32400 | 1.84 | EPA 4627675 → |
CSAH*4212AM*+ furnace: PG80MS(A,L)A48090C**Cold climate designationAHRI reference: 218477492 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627677 → |
CSAH*4212AM*+ furnace: PG80MS(A,L)A42090B**Cold climate designationAHRI reference: 218477488 | 15.20 | 8.50 | 32400 | 1.84 | EPA 4627679 → |
CSAH*4212AM*+ furnace: PG80MS(A,L)A48070C**Cold climate designationAHRI reference: 218477484 | 15.20 | 8.50 | 32400 | 1.82 | EPA 4627681 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →