PAYNE HEATING AND COOLING / AIR-SOURCE HEAT PUMP

37MUHAQ24AA3+KSAIC0701230

Crossover Heat Pump · source records, page 3

373 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity22,600–25,000BTU/h

Each efficiency range summarizes published EPA records for 37MUHAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 373 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18373 / 373
EER2 · BTU/Wh10–11373 / 373
HSPF2 · BTU/Wh8.1–9.5373 / 373
Cooling capacity · BTU/h22,600–25,000373 / 373
Heating capacity at 47°F / 8.3°C · BTU/h22,200–23,800373 / 373
Heating capacity at 17°F / −8.3°C · BTU/h16,800–18,100373 / 373
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000373 / 373
COP at 5°F / −15°C1.85–2.06373 / 373
Equipment / loop typeHP - Split System373 / 373
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)373 / 373
Compressor stagingContinuously variable373 / 373
Connected capabilityNo373 / 373

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: PG80VTLB48090B**Cold climate designationAHRI reference: 21847693917.008.50191001.92EPA 4626501 →
CAA**3717AM*+ furnace: PG80VTLB48070B**Cold climate designationAHRI reference: 21847693717.008.50191001.92EPA 4626503 →
CAA**3717AM*+ furnace: PG80MSUA36040B**Cold climate designationAHRI reference: 21847692917.008.50191001.92EPA 4626511 →
CAA**3617AM*+ furnace: PG97VTAA48080B**Cold climate designationAHRI reference: 21847692017.008.50194001.90EPA 4626520 →
CAA**3617AM*+ furnace: PG96VTAB48080B**Cold climate designationAHRI reference: 21847691617.008.50194001.90EPA 4626524 →
CAA**3617AM*+ furnace: PG95MSUA48060B**Cold climate designationAHRI reference: 21847690617.008.50194001.88EPA 4626534 →
CAA**3617AM*+ furnace: PG80VTLB48090B**Cold climate designationAHRI reference: 21847689717.008.50194001.90EPA 4626543 →
CAA**3617AM*+ furnace: PG80VTLB48070B**Cold climate designationAHRI reference: 21847689517.008.50194001.90EPA 4626545 →
CAA**3617AM*+ furnace: PG80VTLB36045A**Cold climate designationAHRI reference: 21847689117.008.50194001.90EPA 4626549 →
CAA**3017AM*+ furnace: PG95MSUA48060B**Cold climate designationAHRI reference: 21847686417.008.50195001.90EPA 4626576 →
CAA**3017AM*+ furnace: PG80VTLB48090B**Cold climate designationAHRI reference: 21847685517.008.50195001.88EPA 4626585 →
CAA**3017AM*+ furnace: PG80VTLB48070B**Cold climate designationAHRI reference: 21847685317.008.50195001.90EPA 4626587 →
CAA**3017AM*+ furnace: PG80VTLB36045A**Cold climate designationAHRI reference: 21847684917.008.50195001.90EPA 4626591 →
CAA**3017AM*+ furnace: PG80MSUA48060B**Cold climate designationAHRI reference: 21847684717.008.50194001.90EPA 4626593 →
CAA**3017AM*+ furnace: PG80MSUA36040B**Cold climate designationAHRI reference: 21847684517.008.50195001.88EPA 4626595 →
CAA**3014AM*+ furnace: PG80VTLB36070A**Cold climate designationAHRI reference: 21847683317.008.50195001.88EPA 4626607 →
CAA**2517AM*+ furnace: PG97VTAA48080B**Cold climate designationAHRI reference: 21847682417.009.00191002.02EPA 4626616 →
CAA**2517AM*+ furnace: PG97VTAA48060B**Cold climate designationAHRI reference: 21847682217.008.50190001.92EPA 4626618 →
CAA**2517AM*+ furnace: PG96VTAB48080B**Cold climate designationAHRI reference: 21847682017.009.00191002.02EPA 4626620 →
CAA**2517AM*+ furnace: PG96VTAB48060B**Cold climate designationAHRI reference: 21847681817.008.50190001.92EPA 4626622 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →