37MUHAQ24AA3+KSAIC0701230
Crossover Heat Pump · source records, page 14
373 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 373 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 373 / 373 |
| EER2 · BTU/Wh | 10–11 | 373 / 373 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 373 / 373 |
| Cooling capacity · BTU/h | 22,600–25,000 | 373 / 373 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–23,800 | 373 / 373 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,100 | 373 / 373 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,000 | 373 / 373 |
| COP at 5°F / −15°C | 1.85–2.06 | 373 / 373 |
| Equipment / loop type | HP - Split System | 373 / 373 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 373 / 373 |
| Compressor staging | Continuously variable | 373 / 373 |
| Connected capability | No | 373 / 373 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*3012AM*+ furnace: PG80MSUA60100C**Cold climate designationAHRI reference: 218477114 | 16.00 | 8.50 | 19600 | 1.90 | EPA 4627869 → |
CSAH*2412AM*+ furnace: PG97VTAA66120D**Cold climate designationAHRI reference: 218477096 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4627884 → |
CSAH*2412AM*+ furnace: PG97VTAA60100C**Cold climate designationAHRI reference: 218477093 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4627887 → |
CSAH*2412AM*+ furnace: PG97VTAA60080C**Cold climate designationAHRI reference: 218477091 | 16.00 | 8.50 | 19700 | 1.92 | EPA 4627889 → |
CSAH*2412AM*+ furnace: PG97VTAA48060B**Cold climate designationAHRI reference: 218477087 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4627893 → |
CSAH*2412AM*+ furnace: PG96VTAB66120D**Cold climate designationAHRI reference: 218477085 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4627895 → |
CSAH*2412AM*+ furnace: PG96VTAB60100C**Cold climate designationAHRI reference: 218477082 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4627898 → |
CSAH*2412AM*+ furnace: PG96VTAB60080C**Cold climate designationAHRI reference: 218477080 | 16.00 | 8.50 | 19700 | 1.92 | EPA 4627900 → |
CSAH*2412AM*+ furnace: PG96VTAB48060B**Cold climate designationAHRI reference: 218477076 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4627904 → |
CSAH*2412AM*+ furnace: PG96VTAB36060A**Cold climate designationAHRI reference: 218477074 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4627906 → |
CSAH*2412AM*+ furnace: PG95MSUA48060B**Cold climate designationAHRI reference: 218477063 | 16.00 | 8.50 | 19800 | 1.88 | EPA 4627915 → |
CSAH*2412AM*+ furnace: PG80VTLB48090B**Cold climate designationAHRI reference: 218477045 | 16.00 | 8.50 | 19700 | 1.90 | EPA 4627933 → |
CSAH*2412AM*+ furnace: PG80VTLB48070B**Cold climate designationAHRI reference: 218477043 | 16.00 | 8.50 | 19800 | 1.88 | EPA 4627935 → |
CSAH*2412AM*+ furnace: PG80VTLB36070A**Cold climate designationAHRI reference: 218477041 | 16.00 | 8.50 | 19700 | 1.90 | EPA 4627937 → |
CSAH*2412AM*+ furnace: PG80VTLB36045A**Cold climate designationAHRI reference: 218477039 | 16.00 | 8.50 | 19700 | 1.90 | EPA 4627939 → |
CSAH*2412AM*+ furnace: PG80MSUA60100C**Cold climate designationAHRI reference: 218477037 | 16.00 | 8.50 | 20000 | 1.88 | EPA 4627941 → |
CSAH*2412AM*+ furnace: PG80MSUA60080C**Cold climate designationAHRI reference: 218477035 | 16.00 | 8.50 | 19700 | 1.90 | EPA 4627943 → |
CSAH*2412AM*+ furnace: PG80MSUA36040B**Cold climate designationAHRI reference: 218477031 | 16.00 | 8.50 | 19700 | 1.90 | EPA 4627947 → |
PF5MN*B36L*Cold climate designationAHRI reference: 218476719 | 15.50 | 9.00 | 19000 | 2.06 | EPA 4626717 → |
FJ5AN*B36L*Cold climate designationAHRI reference: 218476718 | 15.50 | 9.00 | 19000 | 2.06 | EPA 4626718 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →