37MUHAQ18AA3+KSAIC0701230
Crossover Heat Pump · source records, page 2
56 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ18AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 56 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 56 / 56 |
| EER2 · BTU/Wh | 10.5–11 | 56 / 56 |
| HSPF2 · BTU/Wh | 8.1–9 | 56 / 56 |
| Cooling capacity · BTU/h | 17,400–18,400 | 56 / 56 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,900–20,200 | 56 / 56 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,400–15,200 | 56 / 56 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,300–17,400 | 56 / 56 |
| COP at 5°F / −15°C | 1.85–2.04 | 56 / 56 |
| Equipment / loop type | HP - Split System | 56 / 56 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 56 / 56 |
| Compressor staging | Continuously variable | 56 / 56 |
| Connected capability | No | 56 / 56 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3017AM*+ furnace: PG80MSUA48060B**Cold climate designationAHRI reference: 218475555 | 15.50 | 8.10 | 17200 | 1.90 | EPA 4626342 → |
CAA**3017AM*+ furnace: PG80MSUA36040B**Cold climate designationAHRI reference: 218475553 | 15.50 | 8.10 | 17200 | 1.90 | EPA 4626344 → |
CAA**3017AM*+ furnace: PG80MS(A,L)A36070B**Cold climate designationAHRI reference: 218475543 | 15.50 | 8.10 | 16500 | 1.85 | EPA 4626348 → |
CAA**3017AM*+ furnace: PG80MS(A,L)A36070A**Cold climate designationAHRI reference: 218475541 | 15.50 | 8.10 | 16400 | 1.85 | EPA 4626350 → |
FM(C,U)5Z18**AL*Cold climate designationAHRI reference: 218475455 | 15.50 | 9.00 | 17100 | 2.04 | EPA 4626363 → |
FM(C,U)5Z24**AL*Cold climate designationAHRI reference: 218475453 | 15.50 | 9.00 | 17100 | 2.04 | EPA 4626365 → |
CAA**1917AM*+ furnace: PG96VTAB36060A**Cold climate designationAHRI reference: 218475834 | 15.20 | 8.10 | 17000 | 1.90 | EPA 4626252 → |
CAA**1917AM*+ furnace: PG96MSAA48080B**Cold climate designationAHRI reference: 218475819 | 15.20 | 8.50 | 16600 | 1.95 | EPA 4626255 → |
CAA**1917AM*+ furnace: PG96MSAA36060A**Cold climate designationAHRI reference: 218475815 | 15.20 | 8.10 | 16400 | 1.85 | EPA 4626257 → |
CAA**1917AM*+ furnace: PG92MSAA42060B**Cold climate designationAHRI reference: 218475805 | 15.20 | 8.50 | 16500 | 1.95 | EPA 4626261 → |
CAA**1917AM*+ furnace: PG92MSAA36060A**Cold climate designationAHRI reference: 218475803 | 15.20 | 8.10 | 16300 | 1.85 | EPA 4626263 → |
CAA**1917AM*+ furnace: PG80MS(A,L)A42090B**Cold climate designationAHRI reference: 218475787 | 15.20 | 8.50 | 16500 | 1.95 | EPA 4626269 → |
CAA**2414AM*+ furnace: PG80VTLB36070A**Cold climate designationAHRI reference: 218475764 | 15.20 | 8.10 | 17300 | 1.90 | EPA 4626277 → |
CAA**2414AM*+ furnace: PG80MS(A,L)A36070A**Cold climate designationAHRI reference: 218475758 | 15.20 | 8.50 | 16600 | 1.95 | EPA 4626280 → |
CAA**2414AM*+ furnace: PG80MS(A,L)A36045A**Cold climate designationAHRI reference: 218475756 | 15.20 | 8.50 | 16700 | 1.90 | EPA 4626282 → |
CAA**2417AM*+ furnace: PG92MSAA48080B**Cold climate designationAHRI reference: 218475729 | 15.20 | 8.50 | 16600 | 1.95 | EPA 4626285 → |
CAA**2417AM*+ furnace: PG80VTLB36070A**Cold climate designationAHRI reference: 218475721 | 15.20 | 8.10 | 17300 | 1.90 | EPA 4626287 → |
CAA**2417AM*+ furnace: PG80MS(A,L)A36070B**Cold climate designationAHRI reference: 218475705 | 15.20 | 8.50 | 16600 | 1.95 | EPA 4626294 → |
CAA**2417AM*+ furnace: PG80MS(A,L)A36070A**Cold climate designationAHRI reference: 218475703 | 15.20 | 8.50 | 16600 | 1.95 | EPA 4626296 → |
CAA**2417AM*+ furnace: PG80MS(A,L)A36045A**Cold climate designationAHRI reference: 218475699 | 15.20 | 8.50 | 16700 | 1.95 | EPA 4626298 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →