Panasonic / AIR-SOURCE HEAT PUMP

CU-HM30BAHU

CU Series

13 published source records · source checked Sep 21, 2026

SEER2 range15.3–16.8BTU/Wh
HSPF2 range8.4–10BTU/Wh
Cooling capacity29,000–30,000BTU/h

Each efficiency range summarizes published EPA records for CU-HM30BAHU. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 13 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.3–16.813 / 13
EER2 · BTU/Wh10–11.713 / 13
HSPF2 · BTU/Wh8.4–1013 / 13
Cooling capacity · BTU/h29,000–30,00013 / 13
Heating capacity at 47°F / 8.3°C · BTU/h29,000–34,00013 / 13
Heating capacity at 17°F / −8.3°C · BTU/h22,000–25,00013 / 13
Heating capacity at 5°F / −15°C · BTU/h29,000–32,60013 / 13
COP at 5°F / −15°C1.75–1.9613 / 13
Equipment / loop typeHP - Split System13 / 13
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)13 / 13
Compressor stagingContinuously variable13 / 13
Connected capabilityNo13 / 13

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CS-HM30BAHUCold climate designationAHRI reference: 21650588116.8010.00326001.96EPA 3848961
CS-HM36BAAU3+ furnace: S9V2C100D5VS***Cold climate designationAHRI reference: 21790045116.808.70290001.80EPA 4513792
CS-HM36BAAU3+ furnace: S9V2C100U5VS***Cold climate designationAHRI reference: 21790045216.808.70290001.80EPA 4513793
CS-HM36BAAU3+ furnace: S9V2C080U5VS***Cold climate designationAHRI reference: 21790045016.708.60290001.75EPA 4513791
CS-HM36BAAU2Cold climate designationAHRI reference: 21662149916.009.60320001.85EPA 3892332
CS-HM36BAAU3Cold climate designationAHRI reference: 21662150016.009.60320001.85EPA 3892333
CS-HM36BAAU2+ furnace: S9V2B040D3VS***Cold climate designationAHRI reference: 21790044415.608.60290001.75EPA 4513785
CS-HM36BAAU2+ furnace: S9V2B080D4VS***Cold climate designationAHRI reference: 21790044815.608.40290001.75EPA 4513789
CS-HM36BAAU2+ furnace: S9V2B040U3VS***Cold climate designationAHRI reference: 21790044515.508.90290001.80EPA 4513786
CS-HM36BAAU2+ furnace: S9V2B060D3VS***Cold climate designationAHRI reference: 21790044615.508.80290001.80EPA 4513787
CS-HM36BAAU2+ furnace: S9V2B060U4VS***Cold climate designationAHRI reference: 21790044715.508.80290001.80EPA 4513788
CS-HM36BAAU2+ furnace: S9V2B080U4VS***Cold climate designationAHRI reference: 21790044915.508.80290001.80EPA 4513790
CS-HM36BAAU1Cold climate designationAHRI reference: 21662149815.309.30304001.80EPA 3892331

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →