MRCOOL / AIR-SOURCE HEAT PUMP

UHP18024-O

UHP Series

10 published source records · source checked Sep 21, 2026

SEER2 range16–18.6BTU/Wh
HSPF2 range8.9–10BTU/Wh
Cooling capacity24,000BTU/h

Each efficiency range summarizes published EPA records for UHP18024-O. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 10 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18.610 / 10
EER2 · BTU/Wh10–1210 / 10
HSPF2 · BTU/Wh8.9–1010 / 10
Cooling capacity · BTU/h24,00010 / 10
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,00010 / 10
Heating capacity at 17°F / −8.3°C · BTU/h18,000–20,80010 / 10
Heating capacity at 5°F / −15°C · BTU/h20,000–20,60010 / 10
COP at 5°F / −15°C1.8–2.1410 / 10
Equipment / loop typeHP - Split System10 / 10
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)10 / 10
Compressor stagingContinuously variable10 / 10
Connected capabilityNo10 / 10

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
UAH18024 - OCold climate designationAHRI reference: 21773032818.6010.00206002.14EPA 4498594
**AECMPT24B2AA+ furnace: MGM96EE060B3NBCold climate designationAHRI reference: 21802937317.809.20200001.90EPA 4523811
MCMP1824BOTB+ furnace: MGM96EE060B3NBCold climate designationAHRI reference: 21802936117.809.20200001.90EPA 4523822
**AECMPT24B2AA+ furnace: MGM96EE080B3NBCold climate designationAHRI reference: 21802937417.609.30200001.90EPA 4523810
MCMP1824BOTB+ furnace: MGM96EE080B3NBCold climate designationAHRI reference: 21802936217.609.30200001.90EPA 4523821
**AECMPT24B2AA+ furnace: MGA80SE080B4CCold climate designationAHRI reference: 21802946516.709.20200001.80EPA 4523823
MCMP1824BOTB+ furnace: MGA80SE080B4CCold climate designationAHRI reference: 21802945216.709.20200001.80EPA 4523826
**AECMPT24B2AA+ furnace: MGA80SE060B4CCold climate designationAHRI reference: 21802946416.509.10200001.80EPA 4523824
MCMP1824BOTB+ furnace: MGA80SE060B4CCold climate designationAHRI reference: 21802945116.509.10200001.80EPA 4523827
**AECMPT24A2AA+ furnace: MGA80SE040A3CCold climate designationAHRI reference: 21802946316.008.90200001.80EPA 4523825

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →