Midea / AIR-SOURCE HEAT PUMP

MOVD-36HDN10-M20G

X20H-LGWP · source records, page 2

40 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range9–9.5BTU/Wh
Cooling capacity23,000–34,200BTU/h

Each efficiency range summarizes published EPA records for MOVD-36HDN10-M20G. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 40 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–2040 / 40
EER2 · BTU/Wh10.6–1340 / 40
HSPF2 · BTU/Wh9–9.540 / 40
Cooling capacity · BTU/h23,000–34,20040 / 40
Heating capacity at 47°F / 8.3°C · BTU/h24,000–34,20040 / 40
Heating capacity at 17°F / −8.3°C · BTU/h19,400–28,00040 / 40
Heating capacity at 5°F / −15°C · BTU/h16,800–24,40040 / 40
COP at 5°F / −15°C1.85–240 / 40
Equipment / loop typeHP - Split System40 / 40
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)40 / 40
Compressor stagingContinuously variable40 / 40
Connected capabilityYes40 / 40

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MC**3036CN10TH+ furnace: MGV97U100C5ACold climate designationAHRI reference: 21775228517.509.00240001.88EPA 4511855
MC**3036CN10TH+ furnace: MGV97U080C4ACold climate designationAHRI reference: 21775228417.509.00240001.88EPA 4511856
MC**4248BN10TH+MEME05B4BCold climate designationAHRI reference: 21775248817.509.00240001.88EPA 4511928
MC**4248CN10TH+MEME10C5BCold climate designationAHRI reference: 21775248917.509.00242001.90EPA 4511929
MC**3036BN10TH+ furnace: MGV96U060B3CCold climate designationAHRI reference: 21775288717.509.00240001.88EPA 4512003
MC**3036BN10TH+ furnace: MGV96U080B3CCold climate designationAHRI reference: 21775288817.509.00240001.90EPA 4512005
MC**3036CN10TH+ furnace: MGV96U080C4CCold climate designationAHRI reference: 21775288917.509.00240001.88EPA 4512006
MC**3036CN10TH+ furnace: MGV96U100C5CCold climate designationAHRI reference: 21775289017.509.00240001.88EPA 4512007
MC**3036AN10TH+ furnace: MGV97U060B3ACold climate designationAHRI reference: 21775228017.009.00238001.85EPA 4511851
MC**3036AN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 21775228117.009.00238001.85EPA 4511852
MC**3036AN10TH+ furnace: MGV96U060B3CCold climate designationAHRI reference: 21775288517.009.00238001.85EPA 4512001
MC**3036AN10TH+ furnace: MGV96U080B3CCold climate designationAHRI reference: 21775288617.009.00238001.85EPA 4512002
MC**3036BN10TH+MEME05B4BCold climate designationAHRI reference: 21775248616.509.00240001.90EPA 4511926
MC**3036CN10TH+MEME10C5BCold climate designationAHRI reference: 21775248716.509.00240001.88EPA 4511927
MC**3036AN10TH+MEME05A3BCold climate designationAHRI reference: 21775248516.009.00238001.85EPA 4511925
MC**2430AN10THCold climate designationAHRI reference: 21775228815.209.00168001.90EPA 4511859
MC**2430BN10THCold climate designationAHRI reference: 21775228915.209.00168001.90EPA 4511860
MC**4248CN10THCold climate designationAHRI reference: 21775229115.209.00240001.85EPA 4511861
MC**4248BN10THCold climate designationAHRI reference: 21775229015.209.00238001.85EPA 4511862
MC**4248DN10THCold climate designationAHRI reference: 21775229215.209.00240001.85EPA 4511863

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →