Midea / AIR-SOURCE HEAT PUMP

MOVC-24HN10-M152L

M152H

14 published source records · source checked Sep 21, 2026

SEER2 range15.2BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity23,000–23,400BTU/h

Each efficiency range summarizes published EPA records for MOVC-24HN10-M152L. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 14 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.214 / 14
EER2 · BTU/Wh1214 / 14
HSPF2 · BTU/Wh7.814 / 14
Cooling capacity · BTU/h23,000–23,40014 / 14
Heating capacity at 47°F / 8.3°C · BTU/h22,000–22,80014 / 14
Heating capacity at 17°F / −8.3°C · BTU/h12,800–13,80014 / 14
Heating capacity at 5°F / −15°C · BTU/h9,800–10,20014 / 14
COP at 5°F / −15°C1.94–2.0414 / 14
Equipment / loop typeHP - Split System14 / 14
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)14 / 14
Compressor stagingSingle stage14 / 14
Connected capabilityNo14 / 14

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MVME24A1MN10OAAHRI reference: 21750835915.207.80101001.94EPA 4438034
MVME36B1MN10OAAHRI reference: 21750836015.207.80102002.00EPA 4438035
MHVE30B1MN10TBAHRI reference: 21750836315.207.80100002.04EPA 4438036
MHVE36B1MN10TBAHRI reference: 21750838115.207.80100002.04EPA 4438037
MPCE30B1MN10TAAHRI reference: 21750848715.207.80101002.00EPA 4438055
MPCE36B1MN10TAAHRI reference: 21750848815.207.80100001.98EPA 4438056
MPUE30B1MN10TAAHRI reference: 21750849315.207.8098001.98EPA 4438057
MPUE36B1MN10TAAHRI reference: 21750849415.207.8098001.96EPA 4438058
MVME24A1MN10TAAHRI reference: 21750850515.207.80101001.94EPA 4438064
MVME36B1MN10TAAHRI reference: 21750850615.207.80102002.00EPA 4438065
MPUE36B2MN10TAAHRI reference: 21804353615.207.80101002.02EPA 4519521
MPUE30B2MN10TAAHRI reference: 21804353515.207.80101002.02EPA 4519522
MPCE36B2MN10TAAHRI reference: 21804352415.207.80101002.02EPA 4519525
MPCE30B2MN10TAAHRI reference: 21804352315.207.80101002.02EPA 4519526

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →