MOVB-36HDN10-M20G
X20H-LGWP · source records, page 2
40 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for MOVB-36HDN10-M20G. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 40 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 40 / 40 |
| EER2 · BTU/Wh | 10.6–13 | 40 / 40 |
| HSPF2 · BTU/Wh | 9–9.5 | 40 / 40 |
| Cooling capacity · BTU/h | 23,000–34,200 | 40 / 40 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–34,200 | 40 / 40 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,400–28,000 | 40 / 40 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,800–24,400 | 40 / 40 |
| COP at 5°F / −15°C | 1.85–2 | 40 / 40 |
| Equipment / loop type | HP - Split System | 40 / 40 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 40 / 40 |
| Compressor staging | Continuously variable | 40 / 40 |
| Connected capability | No | 40 / 40 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MC**3036CN10TH+ furnace: MGV96U080C4CCold climate designationAHRI reference: 214771645 | 17.50 | 9.00 | 24000 | 1.88 | EPA 3543013 → |
MC**3036CN10TH+ furnace: MGV96U100C5CCold climate designationAHRI reference: 214771646 | 17.50 | 9.00 | 24000 | 1.88 | EPA 3543014 → |
MC**4248BN10TH+MEME05B4BCold climate designationAHRI reference: 217752463 | 17.50 | 9.00 | 24000 | 1.88 | EPA 4511910 → |
MC**4248CN10TH+MEME10C5BCold climate designationAHRI reference: 217752464 | 17.50 | 9.00 | 24200 | 1.90 | EPA 4511911 → |
MC**3036BN10TH+ furnace: MGV97U060B3ACold climate designationAHRI reference: 217752842 | 17.50 | 9.00 | 24000 | 1.88 | EPA 4511953 → |
MC**3036BN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 217752843 | 17.50 | 9.00 | 24000 | 1.90 | EPA 4511954 → |
MC**3036CN10TH+ furnace: MGV97U080C4ACold climate designationAHRI reference: 217752844 | 17.50 | 9.00 | 24000 | 1.88 | EPA 4511955 → |
MC**3036CN10TH+ furnace: MGV97U100C5ACold climate designationAHRI reference: 217752845 | 17.50 | 9.00 | 24000 | 1.88 | EPA 4511956 → |
MC**3036AN10TH+ furnace: MGV96U060B3CCold climate designationAHRI reference: 214771641 | 17.00 | 9.00 | 23800 | 1.85 | EPA 3543009 → |
MC**3036AN10TH+ furnace: MGV96U080B3CCold climate designationAHRI reference: 214771642 | 17.00 | 9.00 | 23800 | 1.85 | EPA 3543010 → |
MC**3036AN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 217752841 | 17.00 | 9.00 | 23800 | 1.85 | EPA 4511951 → |
MC**3036AN10TH+ furnace: MGV97U060B3ACold climate designationAHRI reference: 217752840 | 17.00 | 9.00 | 23800 | 1.85 | EPA 4511952 → |
MC**3036BN10TH+MEME05B4BCold climate designationAHRI reference: 217752461 | 16.50 | 9.00 | 24000 | 1.90 | EPA 4511907 → |
MC**3036CN10TH+MEME10C5BCold climate designationAHRI reference: 217752462 | 16.50 | 9.00 | 24000 | 1.88 | EPA 4511908 → |
MC**3036AN10TH+MEME05A3BCold climate designationAHRI reference: 217752460 | 16.00 | 9.00 | 23800 | 1.85 | EPA 4511909 → |
MC**2430BN10THCold climate designationAHRI reference: 214771650 | 15.20 | 9.00 | 16800 | 1.90 | EPA 3543017 → |
MC**2430AN10THCold climate designationAHRI reference: 214771649 | 15.20 | 9.00 | 16800 | 1.90 | EPA 3543018 → |
MC**4248BN10THCold climate designationAHRI reference: 214771654 | 15.20 | 9.00 | 23800 | 1.85 | EPA 3543019 → |
MC**4248CN10THCold climate designationAHRI reference: 214771655 | 15.20 | 9.00 | 24000 | 1.85 | EPA 3543020 → |
MC**4248DN10THCold climate designationAHRI reference: 214771656 | 15.20 | 9.00 | 24000 | 1.85 | EPA 3543021 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →