Heating performance & equipment details
Ranges include the 120 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 120 / 120 |
| EER2 · BTU/Wh | 10.1–12 | 120 / 120 |
| HSPF2 · BTU/Wh | 8.4–10.3 | 120 / 120 |
| Cooling capacity · BTU/h | 34,000–36,000 | 120 / 120 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,000–38,000 | 120 / 120 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–33,000 | 120 / 120 |
| Heating capacity at 5°F / −15°C · BTU/h | 31,000–39,000 | 120 / 120 |
| COP at 5°F / −15°C | 1.75–1.9 | 120 / 120 |
| Equipment / loop type | HP - Split System | 120 / 120 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 120 / 120 |
| Compressor staging | Continuously variable | 120 / 120 |
| Connected capability | No | 120 / 120 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MAAHE-H36B-CA-UC+ furnace: ML193UH090XE48C*Cold climate designationAHRI reference: 218156566 | 15.20 | 9.30 | 33000 | 1.80 | EPA 4575886 → |
MAAHE-H36B-BA-UC+ furnace: ML296DF070XV48B*Cold climate designationAHRI reference: 218156479 | 15.20 | 8.90 | 33000 | 1.75 | EPA 4575968 → |
MAAHE-H36B-CA-UC+ furnace: ML196UH090XE48B*Cold climate designationAHRI reference: 218156478 | 15.20 | 9.30 | 33000 | 1.80 | EPA 4575969 → |
MAAHE-H36B-CA-UC+ furnace: ML193UH090XE48B*Cold climate designationAHRI reference: 218156474 | 15.20 | 9.30 | 33000 | 1.80 | EPA 4575973 → |
MAAHE-H36B-CA-UC+ furnace: C120-M-VCold climate designationAHRI reference: 218155913 | 15.20 | 9.30 | 34000 | 1.90 | EPA 4576166 → |
MAAHE-H36B-CA-UC+ furnace: C105-M-VCold climate designationAHRI reference: 218155912 | 15.20 | 9.20 | 34000 | 1.80 | EPA 4576167 → |
MAAHE-H36B-CA-UC+ furnace: MGV96U100C5CCold climate designationAHRI reference: 218155882 | 15.20 | 9.30 | 34000 | 1.90 | EPA 4576186 → |
MAAHE-H36B-BA-UC+ furnace: S9V2B060D3VS***Cold climate designationAHRI reference: 218155854 | 15.20 | 9.00 | 33000 | 1.80 | EPA 4576214 → |
MAAHE-H36B-BA-UC+ furnace: S9V2B060U4VS***Cold climate designationAHRI reference: 218155853 | 15.20 | 9.00 | 33000 | 1.80 | EPA 4576215 → |
MAAHE-H36B-CA+ furnace: ML196UH090XE48C*Cold climate designationAHRI reference: 218155813 | 15.20 | 9.30 | 33000 | 1.80 | EPA 4576234 → |
MAAHE-H36B-CA+ furnace: ML193UH090XE48C*Cold climate designationAHRI reference: 218155808 | 15.20 | 9.30 | 33000 | 1.80 | EPA 4576236 → |
MAAHE-H36B-BA+ furnace: ML296DF070XV48B*Cold climate designationAHRI reference: 218155721 | 15.20 | 8.90 | 33000 | 1.75 | EPA 4576318 → |
MAAHE-H36B-CA+ furnace: ML196UH090XE48B*Cold climate designationAHRI reference: 218155720 | 15.20 | 9.30 | 33000 | 1.80 | EPA 4576319 → |
MAAHE-H36B-CA+ furnace: ML193UH090XE48B*Cold climate designationAHRI reference: 218155716 | 15.20 | 9.30 | 33000 | 1.80 | EPA 4576323 → |
MAAHE-H36B-CA+ furnace: C120-M-VCold climate designationAHRI reference: 218155155 | 15.20 | 9.30 | 34000 | 1.90 | EPA 4576516 → |
MAAHE-H36B-CA+ furnace: C105-M-VCold climate designationAHRI reference: 218155154 | 15.20 | 9.20 | 34000 | 1.80 | EPA 4576517 → |
MAAHE-H36B-CA-UC+ furnace: BZ33-96E2U100C5Cold climate designationAHRI reference: 218396924 | 15.20 | 9.30 | 34000 | 1.90 | EPA 4599638 → |
MAAHE-H36B-CA+ furnace: BZ33-96E2U100C5Cold climate designationAHRI reference: 218396897 | 15.20 | 9.30 | 34000 | 1.90 | EPA 4599665 → |
MAAHE-H36B-CA-UC+ furnace: W962V100CU5SAACold climate designationAHRI reference: 218466436 | 15.20 | 9.30 | 34000 | 1.90 | EPA 4624694 → |
MAAHE-H36B-CA+ furnace: W962V100CU5SAACold climate designationAHRI reference: 218466355 | 15.20 | 9.30 | 34000 | 1.90 | EPA 4624724 → |