MO1HE-H60B-2A
MAU Series · MO1 Series · source records, page 2
44 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for MO1HE-H60B-2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 44 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.5 | 44 / 44 |
| EER2 · BTU/Wh | 9.9–12 | 44 / 44 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 44 / 44 |
| Cooling capacity · BTU/h | 47,000–54,000 | 44 / 44 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 51,000–58,000 | 44 / 44 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 35,000–45,000 | 44 / 44 |
| Heating capacity at 5°F / −15°C · BTU/h | 40,000–54,000 | 44 / 44 |
| COP at 5°F / −15°C | 1.8–1.9 | 44 / 44 |
| Equipment / loop type | HP - Split System | 44 / 44 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 44 / 44 |
| Compressor staging | Continuously variable | 44 / 44 |
| Connected capability | No | 44 / 44 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MAAHE-H60B-CA-UC+ furnace: W962V100CU5SAACold climate designationAHRI reference: 218466431 | 15.90 | 8.40 | 41000 | 1.80 | EPA 4624698 → |
MAAHE-H60B-CA+ furnace: W962V100CU5SAACold climate designationAHRI reference: 218466429 | 15.90 | 8.40 | 41000 | 1.80 | EPA 4624700 → |
MAAHE-H60B-CA-UC+ furnace: W801V100CM5SGACold climate designationAHRI reference: 218741665 | 15.90 | 8.10 | 41000 | 1.80 | EPA 4695911 → |
MAAHE-H60B-CA+ furnace: W801V100CM5SGACold climate designationAHRI reference: 218741633 | 15.90 | 8.10 | 41000 | 1.80 | EPA 4695926 → |
MAAHE-H60B-CA-UC+ furnace: MGV80M100C5NBCold climate designationAHRI reference: 218741601 | 15.90 | 8.10 | 41000 | 1.80 | EPA 4695941 → |
MAAHE-H60B-CA+ furnace: MGV80M100C5NBCold climate designationAHRI reference: 218741569 | 15.90 | 8.10 | 41000 | 1.80 | EPA 4695956 → |
MAAHE-H60B-CA-UC+ furnace: C120-M-VCold climate designationAHRI reference: 218155916 | 15.70 | 8.50 | 42000 | 1.80 | EPA 4576163 → |
MAAHE-H60B-CA-UC+ furnace: MGV96U080C4CCold climate designationAHRI reference: 218155885 | 15.70 | 8.60 | 41000 | 1.80 | EPA 4576183 → |
MAAHE-H60B-CA+ furnace: C120-M-VCold climate designationAHRI reference: 218155158 | 15.70 | 8.50 | 42000 | 1.80 | EPA 4576513 → |
MAAHE-H60B-CA+ furnace: MGV96U080C4CCold climate designationAHRI reference: 218155137 | 15.70 | 8.60 | 41000 | 1.80 | EPA 4576533 → |
MAAHE-H60B-CA-UC+ furnace: BZ33-96E2U080C4Cold climate designationAHRI reference: 218396921 | 15.70 | 8.60 | 41000 | 1.80 | EPA 4599641 → |
MAAHE-H60B-CA+ furnace: BZ33-96E2U080C4Cold climate designationAHRI reference: 218396885 | 15.70 | 8.60 | 41000 | 1.80 | EPA 4599677 → |
MAAHE-H60B-CA-UC+ furnace: W962V080CU4SAACold climate designationAHRI reference: 218466432 | 15.70 | 8.60 | 41000 | 1.80 | EPA 4624697 → |
MAAHE-H60B-CA+ furnace: W962V080CU4SAACold climate designationAHRI reference: 218466327 | 15.70 | 8.60 | 41000 | 1.80 | EPA 4624735 → |
MAAHE-H60B-DA-UC+ furnace: MGV96U120D5CCold climate designationAHRI reference: 218155887 | 15.60 | 9.10 | 43000 | 1.80 | EPA 4576181 → |
MAAHE-H60B-DA+ furnace: MGV96U120D5CCold climate designationAHRI reference: 218155139 | 15.60 | 9.10 | 43000 | 1.80 | EPA 4576531 → |
MAAHE-H60B-DA-UC+ furnace: BZ33-96E2U120D5Cold climate designationAHRI reference: 218396919 | 15.60 | 9.10 | 43000 | 1.80 | EPA 4599643 → |
MAAHE-H60B-DA+ furnace: BZ33-96E2U120D5Cold climate designationAHRI reference: 218396917 | 15.60 | 9.10 | 43000 | 1.80 | EPA 4599645 → |
MAAHE-H60B-DA-UC+ furnace: W962V120DU5SAACold climate designationAHRI reference: 218466430 | 15.60 | 9.10 | 43000 | 1.80 | EPA 4624699 → |
MAAHE-H60B-DA+ furnace: W962V120DU5SAACold climate designationAHRI reference: 218466427 | 15.60 | 9.10 | 43000 | 1.80 | EPA 4624701 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →