Midea / AIR-SOURCE HEAT PUMP

MO1HE-H30B-2A

MAU Series · MO1 Series

114 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8.1–10.8BTU/Wh
Cooling capacity28,000–30,000BTU/h

Each efficiency range summarizes published EPA records for MO1HE-H30B-2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 114 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5114 / 114
EER2 · BTU/Wh10–12114 / 114
HSPF2 · BTU/Wh8.1–10.8114 / 114
Cooling capacity · BTU/h28,000–30,000114 / 114
Heating capacity at 47°F / 8.3°C · BTU/h28,000–34,000114 / 114
Heating capacity at 17°F / −8.3°C · BTU/h22,000–25,000114 / 114
Heating capacity at 5°F / −15°C · BTU/h28,000–33,200114 / 114
COP at 5°F / −15°C1.75–2114 / 114
Equipment / loop typeHP - Split System114 / 114
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)114 / 114
Compressor stagingContinuously variable114 / 114
Connected capabilityNo114 / 114

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MAWHE-H30B-2ACold climate designationAHRI reference: 21660726317.5010.20320002.00EPA 3891647 →
MAUSE-H30B-2ACold climate designationAHRI reference: 21547134117.2010.80332001.97EPA 3627891 →
MAUSE-H36B-2ACold climate designationAHRI reference: 21873129717.2010.80332001.97EPA 4695876 →
MAUHE-H30B-2ACold climate designationAHRI reference: 21547133316.8010.00326001.96EPA 3627884 →
MAAHE-H36B-CA-UC+ furnace: S9V2C100U5VS***Cold climate designationAHRI reference: 21815602916.808.70290001.80EPA 4576126 →
MAAHE-H36B-CA-UC+ furnace: S9V2C100D5VS***Cold climate designationAHRI reference: 21815602816.808.70290001.80EPA 4576127 →
MAAHE-H36B-CA+ furnace: S9V2C100U5VS***Cold climate designationAHRI reference: 21815527116.808.70290001.80EPA 4576476 →
MAAHE-H36B-CA+ furnace: S9V2C100D5VS***Cold climate designationAHRI reference: 21815527016.808.70290001.80EPA 4576477 →
MAUHE-H36B-2ACold climate designationAHRI reference: 21873129316.8010.00326001.96EPA 4695880 →
MAAHE-H36B-CA-UC+ furnace: S9V2C080U5VS***Cold climate designationAHRI reference: 21815602716.708.60290001.75EPA 4576128 →
MAAHE-H36B-CA+ furnace: S9V2C080U5VS***Cold climate designationAHRI reference: 21815526916.708.60290001.75EPA 4576478 →
MAPHE-H30B-2ACold climate designationAHRI reference: 21662353516.309.50310001.86EPA 3892398 →
MAAHE-H36B-BA+ furnace: RG19060B12MPS1Cold climate designationAHRI reference: 21760856016.309.20300001.80EPA 4480802 →
MAAHE-H36B-BA-UC+ furnace: RG19060B12MPS1Cold climate designationAHRI reference: 21815585916.309.20300001.80EPA 4576209 →
MAAHE-H36B-CA-UC+ furnace: RL18100C16MPS1Cold climate designationAHRI reference: 21815624716.108.40290001.80EPA 4576039 →
MAAHE-H36B-CA-UC+ furnace: RG19100C20MPS1Cold climate designationAHRI reference: 21815619316.108.40290001.80EPA 4576069 →
MAAHE-H36B-CA+ furnace: RL18100C16MPS1Cold climate designationAHRI reference: 21815548916.108.40290001.80EPA 4576389 →
MAAHE-H36B-CA+ furnace: RG19100C20MPS1Cold climate designationAHRI reference: 21815543516.108.40290001.80EPA 4576419 →
MAAHE-H36B-BACold climate designationAHRI reference: 21662352316.009.60320001.85EPA 3892411 →
MAAHE-H36B-CACold climate designationAHRI reference: 21662352516.009.60320001.85EPA 3892412 →