Heating performance & equipment details
Ranges include the 160 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.6 | 160 / 160 |
| EER2 · BTU/Wh | 9.7–12 | 160 / 160 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 160 / 160 |
| Cooling capacity · BTU/h | 23,000–24,000 | 160 / 160 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–26,000 | 160 / 160 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,800 | 160 / 160 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,600–21,600 | 160 / 160 |
| COP at 5°F / −15°C | 1.75–2.14 | 160 / 160 |
| Equipment / loop type | HP - Split System | 160 / 160 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 160 / 160 |
| Compressor staging | Continuously variable | 160 / 160 |
| Connected capability | No | 160 / 160 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MAAHE-H24B-AA-UC+ furnace: MGV80M060A3NBCold climate designationAHRI reference: 218741583 | 16.40 | 9.10 | 20000 | 1.80 | EPA 4695948 → |
MAAHE-H24B-AA+ furnace: MGV80M060A3NBCold climate designationAHRI reference: 218741551 | 16.40 | 9.10 | 20000 | 1.80 | EPA 4695963 → |
MAAHE-H24B-BA-UC+ furnace: ML296DF045XV36B*Cold climate designationAHRI reference: 218156450 | 16.30 | 9.10 | 20000 | 1.80 | EPA 4575997 → |
MAAHE-H24B-AA-UC+ furnace: MGV80M060A3ACold climate designationAHRI reference: 218155940 | 16.30 | 9.10 | 20000 | 1.80 | EPA 4576157 → |
MAAHE-H24B-BA+ furnace: ML296DF045XV36B*Cold climate designationAHRI reference: 218155692 | 16.30 | 9.10 | 20000 | 1.80 | EPA 4576347 → |
MAAHE-H24B-AA+ furnace: MGV80M060A3ACold climate designationAHRI reference: 218155182 | 16.30 | 9.10 | 20000 | 1.80 | EPA 4576507 → |
MAAHE-H24B-AA-UC+ furnace: W801V060AM3SFACold climate designationAHRI reference: 218466618 | 16.30 | 9.10 | 20000 | 1.80 | EPA 4624644 → |
MAAHE-H24B-AA+ furnace: W801V060AM3SFACold climate designationAHRI reference: 218466567 | 16.30 | 9.10 | 20000 | 1.80 | EPA 4624656 → |
MAAHE-H24B-AA-UC+ furnace: W801V060AM3SEBCold climate designationAHRI reference: 218466502 | 16.30 | 9.10 | 20000 | 1.80 | EPA 4624668 → |
MAAHE-H24B-AA+ furnace: W801V060AM3SEBCold climate designationAHRI reference: 218466414 | 16.30 | 9.10 | 20000 | 1.80 | EPA 4624706 → |
MAAHE-H24B-AA-UC+ furnace: GR9S960403ANCold climate designationAHRI reference: 218156456 | 16.20 | 9.10 | 21000 | 1.80 | EPA 4575991 → |
MAAHE-H24B-BA-UC+ furnace: GR9S920603BNCold climate designationAHRI reference: 218156454 | 16.20 | 9.30 | 20000 | 1.80 | EPA 4575993 → |
MAAHE-H24B-BA-UC+ furnace: ML196UH045XE36B*Cold climate designationAHRI reference: 218156445 | 16.20 | 9.10 | 20000 | 1.80 | EPA 4576002 → |
MAAHE-H24B-AA+ furnace: GR9S960403ANCold climate designationAHRI reference: 218155698 | 16.20 | 9.10 | 21000 | 1.80 | EPA 4576341 → |
MAAHE-H24B-BA+ furnace: GR9S920603BNCold climate designationAHRI reference: 218155696 | 16.20 | 9.30 | 20000 | 1.80 | EPA 4576343 → |
MAAHE-H24B-BA+ furnace: ML196UH045XE36B*Cold climate designationAHRI reference: 218155687 | 16.20 | 9.10 | 20000 | 1.80 | EPA 4576352 → |
MAAHE-H24B-BA-UC+ furnace: GD9T960603BNCold climate designationAHRI reference: 218156467 | 16.10 | 9.30 | 20000 | 1.80 | EPA 4575980 → |
MAAHE-H24B-BA+ furnace: GD9T960603BNCold climate designationAHRI reference: 218155709 | 16.10 | 9.30 | 20000 | 1.80 | EPA 4576330 → |
MAAHE-H24B-AA-UC+ furnace: W801V040AM3SGACold climate designationAHRI reference: 218741646 | 16.10 | 8.90 | 20000 | 1.80 | EPA 4695919 → |
MAAHE-H24B-AA+ furnace: W801V040AM3SGACold climate designationAHRI reference: 218741614 | 16.10 | 8.90 | 20000 | 1.80 | EPA 4695934 → |