Midea / AIR-SOURCE HEAT PUMP

MO1ES-H18B-2A

MAC Series · MCA Series · MCD Series · MDH Series · MDL Series · MFA Series · MFB Series · MSE Series

8 published source records · source checked Sep 21, 2026

SEER2 range18.5–23.8BTU/Wh
HSPF2 range9.8–13.5BTU/Wh
Cooling capacity16,000–18,000BTU/h

Each efficiency range summarizes published EPA records for MO1ES-H18B-2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 8 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18.5–23.88 / 8
EER2 · BTU/Wh12.1–13.38 / 8
HSPF2 · BTU/Wh9.8–13.58 / 8
Cooling capacity · BTU/h16,000–18,0008 / 8
Heating capacity at 47°F / 8.3°C · BTU/h17,000–20,0008 / 8
Heating capacity at 17°F / −8.3°C · BTU/h13,200–15,0008 / 8
Heating capacity at 5°F / −15°C · BTU/h12,800–14,2008 / 8
COP at 5°F / −15°C2.05–2.48 / 8
Equipment / loop typeHP - Mini or Multi Split · HP - Split System8 / 8
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)8 / 8
Compressor stagingContinuously variable8 / 8
Connected capabilityNo8 / 8

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MFAHU-H16B-2ACold climate designationAHRI reference: 21547143123.8013.50131002.16EPA 3627462
MSEHU-H18B-2ACold climate designationAHRI reference: 21547137723.5010.80128002.10EPA 3627410
MFBHU-H18B-2ACold climate designationAHRI reference: 21547143522.3010.40128002.05EPA 3627466
MCAHU-H18B-2ACold climate designationAHRI reference: 21547140322.2012.20131002.24EPA 3627438
MCDHU-H18B-2ACold climate designationAHRI reference: 21547139120.7011.40128002.20EPA 3627424
MDHHU-H18B-2ACold climate designationAHRI reference: 21547141720.0011.30142002.40EPA 3627430
MDLHU-H18B-2ACold climate designationAHRI reference: 21547141020.0010.50140002.20EPA 3627445
MACHU-H18B-2ACold climate designationAHRI reference: 21547134618.509.80130002.30EPA 3627896

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.