Midea / AIR-SOURCE HEAT PUMP

MO1BE-H18B-2A

MAU Series · MO1 Series

24 published source records · source checked Sep 21, 2026

SEER2 range16.1–18.8BTU/Wh
HSPF2 range8.2–9.4BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for MO1BE-H18B-2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 24 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.1–18.824 / 24
EER2 · BTU/Wh11–11.524 / 24
HSPF2 · BTU/Wh8.2–9.424 / 24
Cooling capacity · BTU/h18,00024 / 24
Heating capacity at 47°F / 8.3°C · BTU/h18,000–19,00024 / 24
Heating capacity at 17°F / −8.3°C · BTU/h11,000–12,60024 / 24
Heating capacity at 5°F / −15°C · BTU/h10,000–11,40024 / 24
COP at 5°F / −15°C1.8–2.124 / 24
Equipment / loop typeHP - Split System24 / 24
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)24 / 24
Compressor stagingContinuously variable24 / 24
Connected capabilityNo24 / 24

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MAUHE-H18B-2AAHRI reference: 21547132518.809.10112002.00EPA 4471201
MAUHE-H24B-2AAHRI reference: 21873143618.809.10112002.00EPA 4695882
MAWHE-H18B-2AAHRI reference: 21660725718.509.40114002.10EPA 4479531
MAAHE-H24B-BA-UC+ furnace: ML193DF070XE36B*AHRI reference: 21815642817.708.30100001.80EPA 4576019
MAAHE-H24B-BA+ furnace: ML193DF070XE36B*AHRI reference: 21815567017.708.30100001.80EPA 4576369
MAAHE-H24B-AA-UC+ furnace: RL18060A12MPS1AHRI reference: 21815622917.008.20100001.80EPA 4576051
MAAHE-H24B-AA+ furnace: RL18060A12MPS1AHRI reference: 21815547117.008.20100001.80EPA 4576401
MAPHE-H18B-2AAHRI reference: 21662352916.808.80114001.80EPA 4470461
MAAHE-H24B-BA+ furnace: MGV96U060B3CAHRI reference: 21760853816.408.40100001.90EPA 4480540
MAAHE-H24B-BA-UC+ furnace: MGV96U060B3CAHRI reference: 21815586316.408.40100001.90EPA 4576205
MAAHE-H24B-BA-UC+ furnace: BZ33-96E2U060B3AHRI reference: 21839694316.408.40100001.90EPA 4599619
MAAHE-H24B-BA+ furnace: BZ33-96E2U060B3AHRI reference: 21839689616.408.40100001.90EPA 4599666
MAAHE-H24B-BA-UC+ furnace: W962V060BU3SAAAHRI reference: 21846645916.408.40100001.90EPA 4624676
MAAHE-H24B-BA+ furnace: W962V060BU3SAAAHRI reference: 21846635416.408.40100001.90EPA 4624725
MAAHE-H24B-BA-UC+ furnace: RL18080B12MPS1AHRI reference: 21815623016.208.30100001.90EPA 4576050
MAAHE-H24B-BA+ furnace: RL18080B12MPS1AHRI reference: 21815547216.208.30100001.90EPA 4576400
MAAHE-H24B-BA+ furnace: MGV96U080B3CAHRI reference: 21760853916.108.40100001.90EPA 4480511
MAAHE-H24B-AA-UC+ furnace: RL18040A12MPS1AHRI reference: 21815622816.108.20100001.80EPA 4576052
MAAHE-H24B-BA-UC+ furnace: MGV96U080B3CAHRI reference: 21815586416.108.40100001.90EPA 4576204
MAAHE-H24B-AA+ furnace: RL18040A12MPS1AHRI reference: 21815547016.108.20100001.80EPA 4576402

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →