MDV-V60WMN10T(B)
ATOM X · MDV Series
22 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for MDV-V60WMN10T(B). The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Indoor configuration coverage
3 of 22 EPA records for this model do not list individual indoor units. EPA’s reporting template permits this for multi-split systems. Manufacturer-documented kits are identified on their individual source pages. These rows identify an outdoor-model rating and do not establish a complete matched system or compatibility with an arbitrary indoor unit.
Heating performance & equipment details
Ranges include the 22 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19.5 | 22 / 22 |
| EER2 · BTU/Wh | 9–10.8 | 22 / 22 |
| HSPF2 · BTU/Wh | 8.1–10.1 | 22 / 22 |
| Cooling capacity · BTU/h | 43,000–60,000 | 22 / 22 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–60,000 | 22 / 22 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,000–52,000 | 22 / 22 |
| Heating capacity at 5°F / −15°C · BTU/h | 31,000–45,000 | 22 / 22 |
| COP at 5°F / −15°C | 1.8–1.95 | 22 / 22 |
| Equipment / loop type | HP - Mini or Multi Split · HP - Split System | 22 / 22 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 22 / 22 |
| Compressor staging | Continuously variable | 22 / 22 |
| Connected capability | No | 22 / 22 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Source ratings & listed systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 217992166 | 19.50 | 10.10 | 42000 | 1.90 | EPA 4515349 → |
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 217992172 | 18.25 | 9.65 | 42000 | 1.90 | EPA 4515355 → |
MIH48VMN10Cold climate designationAHRI reference: 217992205 | 18.00 | 9.40 | 41000 | 1.95 | EPA 4515751 → |
MIH54VMN10Cold climate designationAHRI reference: 217992206 | 18.00 | 9.30 | 45000 | 1.95 | EPA 4515752 → |
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 217992162 | 17.00 | 9.20 | 42000 | 1.90 | EPA 4515345 → |
MVME48C2MN10TBCold climate designationAHRI reference: 217992200 | 17.00 | 9.40 | 41000 | 1.95 | EPA 4515746 → |
MVME48C2MN10TDCold climate designationAHRI reference: 218159712 | 17.00 | 9.40 | 41000 | 1.95 | EPA 4576643 → |
MC**4860DN10TH+MEME10D5ACold climate designationAHRI reference: 218467817 | 16.80 | 8.30 | 45000 | 1.80 | EPA 4624739 → |
MC**4860CN10TH+MEME10C5ACold climate designationAHRI reference: 218467818 | 16.70 | 8.30 | 45000 | 1.80 | EPA 4624738 → |
MC**4248BN10TH+MEME05B4ACold climate designationAHRI reference: 218467820 | 16.60 | 8.10 | 39000 | 1.80 | EPA 4624736 → |
MC**4248CN10TH+MEME10C5ACold climate designationAHRI reference: 218467823 | 16.60 | 8.50 | 40000 | 1.80 | EPA 4624747 → |
MC**4248DN10TH+MEME10D5ACold climate designationAHRI reference: 218467819 | 16.30 | 8.40 | 40000 | 1.80 | EPA 4624737 → |
MC**4248BN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 217992190 | 16.00 | 8.50 | 31000 | 1.85 | EPA 4515736 → |
MC**4248CN10TH+ furnace: MGV97U080C4ACold climate designationAHRI reference: 217992191 | 16.00 | 8.50 | 31600 | 1.85 | EPA 4515737 → |
MC**4248CN10TH+ furnace: MGV97U100C5ACold climate designationAHRI reference: 217992192 | 16.00 | 8.50 | 33000 | 1.85 | EPA 4515738 → |
MC**4248DN10TH+ furnace: MGV97U100D5ACold climate designationAHRI reference: 217992193 | 16.00 | 8.50 | 33000 | 1.85 | EPA 4515739 → |
MC**4248DN10TH+ furnace: MGV97U120D5ACold climate designationAHRI reference: 217992194 | 16.00 | 8.50 | 33000 | 1.85 | EPA 4515740 → |
MCPM4860CN10TH+ furnace: MGV97U100C5ACold climate designationAHRI reference: 217992195 | 16.00 | 8.90 | 45000 | 1.80 | EPA 4515741 → |
MCPM4860DN10TH+ furnace: MGV97U100D5ACold climate designationAHRI reference: 217992196 | 16.00 | 8.90 | 45000 | 1.90 | EPA 4515742 → |
MCPM4860DN10TH+ furnace: MGV97U120D5ACold climate designationAHRI reference: 217992197 | 16.00 | 8.90 | 45000 | 1.90 | EPA 4515743 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →