Midea / AIR-SOURCE HEAT PUMP

MDV-V36WMN10T(B)

ATOM X · MDV Series

18 published source records · source checked Sep 21, 2026

SEER2 range15.7–20BTU/Wh
HSPF2 range8.1–10.1BTU/Wh
Cooling capacity32,600–36,000BTU/h

Each efficiency range summarizes published EPA records for MDV-V36WMN10T(B). The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Indoor configuration coverage

3 of 18 EPA records for this model do not list individual indoor units. EPA’s reporting template permits this for multi-split systems. Manufacturer-documented kits are identified on their individual source pages. These rows identify an outdoor-model rating and do not establish a complete matched system or compatibility with an arbitrary indoor unit.

Heating performance & equipment details

Ranges include the 18 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.7–2018 / 18
EER2 · BTU/Wh9.7–13.318 / 18
HSPF2 · BTU/Wh8.1–10.118 / 18
Cooling capacity · BTU/h32,600–36,00018 / 18
Heating capacity at 47°F / 8.3°C · BTU/h34,200–40,00018 / 18
Heating capacity at 17°F / −8.3°C · BTU/h27,800–31,20018 / 18
Heating capacity at 5°F / −15°C · BTU/h32,000–36,00018 / 18
COP at 5°F / −15°C1.85–218 / 18
Equipment / loop typeHP - Mini or Multi Split · HP - Split System18 / 18
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)18 / 18
Compressor stagingContinuously variable18 / 18
Connected capabilityNo18 / 18

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Source ratings & listed systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 21799216420.0010.10340002.00EPA 4515347
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 21799216518.909.85340002.00EPA 4515348
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 21799216117.809.60340002.00EPA 4515344
MVME36B2MN10TBCold climate designationAHRI reference: 21799219917.209.40360001.90EPA 4515745
MVME36B2MN10TDCold climate designationAHRI reference: 21815971117.209.40360001.90EPA 4576644
MIH36VMN10Cold climate designationAHRI reference: 21799220417.009.40360001.90EPA 4515750
MC**4248BN10TH+MEME05B4ACold climate designationAHRI reference: 21846781317.008.70320002.00EPA 4624742
MC**3036BN10TH+MEME05B4ACold climate designationAHRI reference: 21846781516.308.20320001.90EPA 4624741
MC**3036AN10TH+ furnace: MGV97U060B3ACold climate designationAHRI reference: 21799218216.008.50342001.85EPA 4515728
MC**3036AN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 21799218316.008.50342001.85EPA 4515729
MCPM3036BN10TH+ furnace: MGV97U060B3ACold climate designationAHRI reference: 21799218416.008.50342001.85EPA 4515730
MCPM3036BN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 21799218516.008.90360001.90EPA 4515731
MC**3036CN10TH+ furnace: MGV97U080C4ACold climate designationAHRI reference: 21799218616.008.50360001.90EPA 4515732
MC**3036CN10TH+ furnace: MGV97U100C5ACold climate designationAHRI reference: 21799218716.008.50360001.90EPA 4515733
MC**4248BN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 21799218816.008.50360001.90EPA 4515734
MC**4248CN10TH+ furnace: MGV97U100C5ACold climate designationAHRI reference: 21799218916.008.50360001.90EPA 4515735
MC**3036AN10TH+MEME05A3ACold climate designationAHRI reference: 21846781616.008.10320001.90EPA 4624740
MC**4248CN10TH+MEME10C5ACold climate designationAHRI reference: 21846781215.708.70320002.00EPA 4624743

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →