Midea / AIR-SOURCE HEAT PUMP

MDV-V24WMN10T(B)

ATOM X · MDV Series

14 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range8.4–10BTU/Wh
Cooling capacity18,000–24,400BTU/h

Each efficiency range summarizes published EPA records for MDV-V24WMN10T(B). The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Indoor configuration coverage

3 of 14 EPA records for this model do not list individual indoor units. EPA’s reporting template permits this for multi-split systems. Manufacturer-documented kits are identified on their individual source pages. These rows identify an outdoor-model rating and do not establish a complete matched system or compatibility with an arbitrary indoor unit.

Heating performance & equipment details

Ranges include the 14 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.514 / 14
EER2 · BTU/Wh9.6–1214 / 14
HSPF2 · BTU/Wh8.4–1014 / 14
Cooling capacity · BTU/h18,000–24,40014 / 14
Heating capacity at 47°F / 8.3°C · BTU/h18,000–26,00014 / 14
Heating capacity at 17°F / −8.3°C · BTU/h15,600–21,00014 / 14
Heating capacity at 5°F / −15°C · BTU/h16,800–20,00014 / 14
COP at 5°F / −15°C1.8–214 / 14
Equipment / loop typeHP - Mini or Multi Split · HP - Split System14 / 14
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)14 / 14
Compressor stagingContinuously variable14 / 14
Connected capabilityNo14 / 14

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Source ratings & listed systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 21799216318.5010.00200001.80EPA 4515346
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 21799217117.759.50200001.80EPA 4515354
MVME24B2MN10TBCold climate designationAHRI reference: 21799219817.709.20200001.90EPA 4515744
MVME24B2MN10TDCold climate designationAHRI reference: 21815971017.709.20200001.90EPA 4576645
Indoor configuration not listed by EPAOutdoor-model rating; match not listedCold climate designationAHRI reference: 21799216017.009.00200001.80EPA 4515343
MIH18VMN10Cold climate designationAHRI reference: 21799220217.009.25180001.95EPA 4515748
MIH24VMN10Cold climate designationAHRI reference: 21799220317.009.20200001.90EPA 4515749
MC**2430AN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 21799217816.008.50168001.80EPA 4515724
MC**2430AN10TH+ furnace: MGV97U060B3ACold climate designationAHRI reference: 21799217916.008.50168001.80EPA 4515725
MC**2430BN10TH+ furnace: MGV97U060B3ACold climate designationAHRI reference: 21799218016.008.60200001.80EPA 4515726
MC**2430BN10TH+ furnace: MGV97U080B3ACold climate designationAHRI reference: 21799218116.008.90200001.85EPA 4515727
MC**2430AN10TH+MEME05A3ACold climate designationAHRI reference: 21846781115.208.40200002.00EPA 4624744
MC**2430BN10TH+MEME05B4ACold climate designationAHRI reference: 21846781015.208.40200002.00EPA 4624745
MC**3036BN10TH+MEME05B4ACold climate designationAHRI reference: 21846780915.208.40200002.00EPA 4624746

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →