MDV / AIR-SOURCE HEAT PUMP

MOX430-18HFN10-M1X

MCA Series · MCB Series · MFA Series · MSAG series · MSEP Series · MSEP seris · MT Series · MTI Series · MTJ Series · MUE Series · MUE series · MVB Series

17 published source records · source checked Sep 21, 2026

SEER2 range18–21.7BTU/Wh
HSPF2 range10–12.4BTU/Wh
Cooling capacity16,000–18,000BTU/h

Each efficiency range summarizes published EPA records for MOX430-18HFN10-M1X. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 17 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–21.717 / 17
EER2 · BTU/Wh12–1317 / 17
HSPF2 · BTU/Wh10–12.417 / 17
Cooling capacity · BTU/h16,000–18,00017 / 17
Heating capacity at 47°F / 8.3°C · BTU/h17,000–20,00017 / 17
Heating capacity at 17°F / −8.3°C · BTU/h14,000–18,00017 / 17
Heating capacity at 5°F / −15°C · BTU/h17,000–18,00017 / 17
COP at 5°F / −15°C1.86–2.217 / 17
Equipment / loop typeHP - Mini or Multi Split · HP - Split System17 / 17
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)17 / 17
Compressor stagingContinuously variable17 / 17
Connected capabilityNo17 / 17

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MSAG11D-18HRFN10-M1Cold climate designationAHRI reference: 21431111721.7010.80180002.00EPA 3417738 →
MSEPC-18HRFN10-M1Cold climate designationAHRI reference: 21431111621.5011.00180001.92EPA 3995612 →
MSEPC-18HRFN10-M1-DCold climate designationAHRI reference: 21485556721.4011.00180001.92EPA 3553194 →
MCB-18HRFN10-M1Cold climate designationAHRI reference: 21485541420.7012.20175001.89EPA 3893398 →
MCB-18HRFN10-M1-DCold climate designationAHRI reference: 21485556820.6012.20175001.89EPA 3553195 →
MUE-18HRFN10-M1Cold climate designationAHRI reference: 21485548320.5010.30170001.86EPA 3893432 →
MUE-18HRFN10-M1-DCold climate designationAHRI reference: 21485557120.4010.30170001.86EPA 3553197 →
MFA2-16HRFN10-M1Cold climate designationAHRI reference: 21485541620.2010.30175001.95EPA 3553408 →
MCA4-18HRFN10-M1-DCold climate designationAHRI reference: 21485556920.0012.30170001.90EPA 3553196 →
MFA2-16HRFN10-M1-DCold climate designationAHRI reference: 21485557020.0010.30175001.95EPA 3553429 →
MCA4-18HRFN10-M1Cold climate designationAHRI reference: 21485541520.0012.40170001.90EPA 3893399 →
MTJ-18HWFN10-M1Cold climate designationAHRI reference: 21486192818.5011.10180002.10EPA 3893489 →
MTJ-18HWFN10-M1-DCold climate designationAHRI reference: 21486194318.4011.10180002.10EPA 3553307 →
MVBC-18HWFN10-MB1Cold climate designationAHRI reference: 21486152818.2010.10180002.20EPA 3553659 →
MTI-18HWFN10-M1-DCold climate designationAHRI reference: 21486194218.0010.50180002.00EPA 3553306 →
MVBC-18HWFN10-MB1-DCold climate designationAHRI reference: 21486157218.0010.00180002.20EPA 3553620 →
MTI-18HWFN10-M1Cold climate designationAHRI reference: 21485541718.0010.80180002.00EPA 3554437 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.