MDV / AIR-SOURCE HEAT PUMP

MOX430-18HFN10-M1

MCA Series · MCB Series · MFA Series · MSAB Series · MSAG Series · MSEP Series · MT Series · MTI Series · MTJ Series · MUE Series · MUE series · MVB Series

18 published source records · source checked Sep 21, 2026

SEER2 range18.5–24BTU/Wh
HSPF2 range9.8–13.5BTU/Wh
Cooling capacity16,000–18,000BTU/h

Each efficiency range summarizes published EPA records for MOX430-18HFN10-M1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 18 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18.5–2418 / 18
EER2 · BTU/Wh12.1–13.518 / 18
HSPF2 · BTU/Wh9.8–13.518 / 18
Cooling capacity · BTU/h16,000–18,00018 / 18
Heating capacity at 47°F / 8.3°C · BTU/h17,000–20,00018 / 18
Heating capacity at 17°F / −8.3°C · BTU/h13,200–15,00018 / 18
Heating capacity at 5°F / −15°C · BTU/h12,800–14,20018 / 18
COP at 5°F / −15°C2.05–2.418 / 18
Equipment / loop typeHP - Mini or Multi Split · HP - Split System18 / 18
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)18 / 18
Compressor stagingContinuously variable18 / 18
Connected capabilityNo18 / 18

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MSAG11D-18HRFN10-M1Cold climate designationAHRI reference: 21485544624.0011.10130002.35EPA 3893419
MFA2-16HRFN10-M1Cold climate designationAHRI reference: 21485545023.9013.50131002.16EPA 3553412
MFA2-16HRFN10-M1-DCold climate designationAHRI reference: 21485552723.8013.50131002.16EPA 3553422
MSAB3E-18HRFN10-M1Cold climate designationAHRI reference: 21485544523.7011.90134002.40EPA 3893418
MSEPC-18HRFN10-M1-DCold climate designationAHRI reference: 21485552423.5010.80128002.10EPA 3553182
MSEPC-18HRFN10-M1Cold climate designationAHRI reference: 21485544723.5010.80128002.10EPA 3893420
MUE-18HRFN10-M1Cold climate designationAHRI reference: 21485548622.4010.40128002.05EPA 3893435
MUE-18HRFN10-M1-DCold climate designationAHRI reference: 21485552822.3010.40128002.05EPA 3553185
MCB-18HRFN10-M1Cold climate designationAHRI reference: 21485544822.3012.20131002.24EPA 3893421
MCB-18HRFN10-M1-DCold climate designationAHRI reference: 21485552522.2012.20131002.24EPA 3553183
MCA4-18HRFN10-M1Cold climate designationAHRI reference: 21485544920.8011.40128002.20EPA 3893422
MCA4-18HRFN10-M1-DCold climate designationAHRI reference: 21485552620.7011.40128002.20EPA 3553184
MTI-18HWFN10-M1-DCold climate designationAHRI reference: 21486195120.0010.50140002.20EPA 3553315
MTI-18HWFN10-M1Cold climate designationAHRI reference: 21485545120.0010.60140002.20EPA 3554441
MTJ-18HWFN10-M1Cold climate designationAHRI reference: 21486193320.0011.40142002.40EPA 3893494
MTJ-18HWFN10-M1-DCold climate designationAHRI reference: 21486195220.0011.30142002.40EPA 3893495
MVBC-18HWFN10-MB1-DCold climate designationAHRI reference: 21486158118.509.80130002.30EPA 3553628
MVBC-18HWFN10-MB1Cold climate designationAHRI reference: 21486153518.509.80130002.30EPA 3553664

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.