MOX330-18HFN10-M3
MOX Series · MVB Series · MVBE Series
14 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for MOX330-18HFN10-M3. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 14 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.1–18.8 | 14 / 14 |
| EER2 · BTU/Wh | 11–11.5 | 14 / 14 |
| HSPF2 · BTU/Wh | 8.2–9.4 | 14 / 14 |
| Cooling capacity · BTU/h | 18,000 | 14 / 14 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,000–19,000 | 14 / 14 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 11,000–12,600 | 14 / 14 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,000–11,400 | 14 / 14 |
| COP at 5°F / −15°C | 1.8–2.1 | 14 / 14 |
| Equipment / loop type | HP - Split System | 14 / 14 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 14 / 14 |
| Compressor staging | Continuously variable | 14 / 14 |
| Connected capability | No | 14 / 14 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MVBC-18HWFN10-MB3EAHRI reference: 214861551 | 18.80 | 9.20 | 11200 | 2.00 | EPA 3943196 → |
MVBC-18HWFN10-MB3E-DAHRI reference: 214861597 | 18.80 | 9.10 | 11200 | 2.00 | EPA 3943197 → |
MVBC-24HWFN10-MB3E-DAHRI reference: 215359328 | 18.80 | 9.10 | 11200 | 2.00 | EPA 3943201 → |
MVBC-18HWFPN10-MB3EAHRI reference: 215865880 | 18.80 | 9.10 | 11200 | 2.00 | EPA 3943204 → |
MVBC-18HWFN10-MB3E-MASAHRI reference: 216030936 | 18.80 | 9.10 | 11200 | 2.00 | EPA 3943207 → |
MVBE-18HWFN10-WM3EAHRI reference: 215894242 | 18.50 | 9.40 | 11400 | 2.10 | EPA 3943206 → |
MVBE-18HWFN10-WM3E-MASAHRI reference: 216030947 | 18.50 | 9.40 | 11400 | 2.10 | EPA 3943209 → |
MVBM-24B18T3N10+ furnace: ML193DF070XE36B*AHRI reference: 217754134 | 17.70 | 8.30 | 10000 | 1.80 | EPA 4511041 → |
MVBM-24A18T3N10+ furnace: RL18060A12MPS1AHRI reference: 217753579 | 17.00 | 8.20 | 10000 | 1.80 | EPA 4511003 → |
MVBL-18HWFN10-MH3AHRI reference: 216620297 | 16.80 | 8.80 | 11400 | 1.80 | EPA 3995942 → |
MVBM-24B18T3N10+ furnace: MGV96U060B3CAHRI reference: 217607689 | 16.40 | 8.40 | 10000 | 1.90 | EPA 4479812 → |
MVBM-24B18T3N10+ furnace: RL18080B12MPS1AHRI reference: 217753580 | 16.20 | 8.30 | 10000 | 1.90 | EPA 4511004 → |
MVBM-24B18T3N10+ furnace: MGV96U080B3CAHRI reference: 217607690 | 16.10 | 8.40 | 10000 | 1.90 | EPA 4480499 → |
MVBM-24A18T3N10+ furnace: RL18040A12MPS1AHRI reference: 217753578 | 16.10 | 8.20 | 10000 | 1.80 | EPA 4511002 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →