MDV / AIR-SOURCE HEAT PUMP

MOX330-09HFN1-MY5W

MCA series · MCBU series · MS11M series · MSAG series · MSEP seris · MTI series

8 published source records · source checked Sep 21, 2026

SEER2 range20.2–28.1BTU/Wh
HSPF2 range10–12.4BTU/Wh
Cooling capacity9,000BTU/h

Each efficiency range summarizes published EPA records for MOX330-09HFN1-MY5W. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 8 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh20.2–28.18 / 8
EER2 · BTU/Wh13–16.28 / 8
HSPF2 · BTU/Wh10–12.48 / 8
Cooling capacity · BTU/h9,0008 / 8
Heating capacity at 47°F / 8.3°C · BTU/h9,800–12,0008 / 8
Heating capacity at 17°F / −8.3°C · BTU/h7,100–10,1008 / 8
Heating capacity at 5°F / −15°C · BTU/h9,800–11,0008 / 8
COP at 5°F / −15°C1.59–28 / 8
Equipment / loop typeHP - Mini or Multi Split8 / 8
Refrigerant / source-reported GWPR-410A (GWP:2088)8 / 8
Compressor stagingContinuously variable8 / 8
Connected capabilityNo8 / 8

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MSEPB-09HRFN1-MY5W(GA)Cold climate designationAHRI reference: 20599384528.1011.50106002.00EPA 2407691
MSAG11B-09HRFN1-MX7W(GA)Cold climate designationAHRI reference: 20636186026.4011.60110001.85EPA 2407666
CS11M-09HRFN1-MX0W(A)AHRI reference: 20599385225.0011.0098001.59EPA 2407688
MCBU-09HRFN1-MU0-CACold climate designationAHRI reference: 21085728924.0012.40105001.80EPA 2407508
MCBU-09HRFN1-MW0WCold climate designationAHRI reference: 20927021024.0012.40105001.80EPA 2407534
MTI-09HWFN1-MSS8Cold climate designationAHRI reference: 21029930320.5010.00108001.90EPA 2407527
MCA3U-09HRFN1-M(C)Cold climate designationAHRI reference: 20633012220.5010.30100001.80EPA 2407680
MTIU-09HWFN1-MCold climate designationAHRI reference: 20633012320.2012.00108001.90EPA 2407679

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.