MDV / AIR-SOURCE HEAT PUMP

MOX230-12HFN10-M1

MCA Series · MCB Series · MFA Series · MSAB Series · MSAG Series · MSEP Series · MT Series · MTI Series · MTJ Series

14 published source records · source checked Sep 21, 2026

SEER2 range19–25.5BTU/Wh
HSPF2 range10–11.5BTU/Wh
Cooling capacity11,500–12,000BTU/h

Each efficiency range summarizes published EPA records for MOX230-12HFN10-M1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 14 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19–25.514 / 14
EER2 · BTU/Wh11.7–13.114 / 14
HSPF2 · BTU/Wh10–11.514 / 14
Cooling capacity · BTU/h11,500–12,00014 / 14
Heating capacity at 47°F / 8.3°C · BTU/h12,00014 / 14
Heating capacity at 17°F / −8.3°C · BTU/h8,500–10,40014 / 14
Heating capacity at 5°F / −15°C · BTU/h8,400–8,90014 / 14
COP at 5°F / −15°C2.2–2.514 / 14
Equipment / loop typeHP - Mini or Multi Split14 / 14
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)14 / 14
Compressor stagingContinuously variable14 / 14
Connected capabilityNo14 / 14

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MSEPBM-12HRFN10-M1-DCold climate designationAHRI reference: 21485552025.5010.6084002.30EPA 3553179
MSEPBM-12HRFN10-M1Cold climate designationAHRI reference: 21485544025.5010.7084002.30EPA 3893415
MFA2M-12HRFN10-M1Cold climate designationAHRI reference: 21485544324.7011.0089002.50EPA 3553413
MFA2M-12HRFN10-M1-DCold climate designationAHRI reference: 21485552324.6011.0089002.50EPA 3553419
MSAB3BM-12HRFN10-M1Cold climate designationAHRI reference: 21485543823.1010.2084002.20EPA 3893413
MSAG11BM-12HRFN10-M1Cold climate designationAHRI reference: 21485543923.1011.5086002.35EPA 3893414
MCBM-12HRFN10-M1Cold climate designationAHRI reference: 21485544122.2010.1086002.48EPA 3893416
MCBM-12HRFN10-M1-DCold climate designationAHRI reference: 21485552122.1010.0086002.48EPA 3553180
MCA4M-12HRFN10-M1Cold climate designationAHRI reference: 21485544221.2010.4084002.40EPA 3893417
MCA4M-12HRFN10-M1-DCold climate designationAHRI reference: 21485552221.1010.4084002.40EPA 3553181
MTJM-12HWFN10-M1-DCold climate designationAHRI reference: 21486195019.5010.5089002.44EPA 3553314
MTJM-12HWFN10-M1Cold climate designationAHRI reference: 21486193219.5010.5089002.44EPA 3893493
MTIM-12HWFN10-M1-DCold climate designationAHRI reference: 21486194919.0010.2088002.25EPA 3553313
MTIM-12HWFN10-M1Cold climate designationAHRI reference: 21485544419.0010.3088002.25EPA 3554439

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →