MOX230-09HFN1-MW5W
MCA series · MCBU series · MSAB series · MSAG series · MSEP seris · MTI series
10 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for MOX230-09HFN1-MW5W. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 10 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19.2–26.5 | 10 / 10 |
| EER2 · BTU/Wh | 12.5–15.8 | 10 / 10 |
| HSPF2 · BTU/Wh | 10–13.6 | 10 / 10 |
| Cooling capacity · BTU/h | 6,000–9,000 | 10 / 10 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 7,000–11,000 | 10 / 10 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 5,700–8,500 | 10 / 10 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,100–8,000 | 10 / 10 |
| COP at 5°F / −15°C | 1.84–2.34 | 10 / 10 |
| Equipment / loop type | HP - Mini or Multi Split | 10 / 10 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 10 / 10 |
| Compressor staging | Continuously variable | 10 / 10 |
| Connected capability | No | 10 / 10 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MSEPB-06HRFN1-MY5WCold climate designationAHRI reference: 207178564 | 26.50 | 13.60 | 7500 | 2.10 | EPA 2407642 → |
MSEPB-09HRFN1-MY5W(GA)Cold climate designationAHRI reference: 206369558 | 25.50 | 12.30 | 7500 | 2.17 | EPA 2407657 → |
MSABB-09HRFN1-MX0WCold climate designationAHRI reference: 207591144 | 24.00 | 11.40 | 7800 | 2.18 | EPA 2407622 → |
MSAG11B-09HRFN1-MX7W(GA)Cold climate designationAHRI reference: 207215956 | 24.00 | 11.60 | 7500 | 2.25 | EPA 2407638 → |
MSAG11A-06HRFN1-MU0WCold climate designationAHRI reference: 207178565 | 23.50 | 12.00 | 7100 | 1.84 | EPA 2407641 → |
MCBU-09HRFN1-MW0WCold climate designationAHRI reference: 209270209 | 22.50 | 11.50 | 7700 | 2.34 | EPA 2407535 → |
MCBU-09HRFN1-MU0-CACold climate designationAHRI reference: 210857291 | 22.00 | 10.80 | 8000 | 2.00 | EPA 2407506 → |
MCBU-06HRFN1-MV0WCold climate designationAHRI reference: 209270213 | 22.00 | 10.80 | 8000 | 2.00 | EPA 2407531 → |
MCA3U-09HRFN1-M(C)Cold climate designationAHRI reference: 206330118 | 20.00 | 10.00 | 7400 | 1.90 | EPA 2407684 → |
MTIU-09HWFN1-MCold climate designationAHRI reference: 206330121 | 19.20 | 10.20 | 8000 | 2.10 | EPA 2407681 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →