R5H5S31*K*AAA*
15 SEER2 HP
33 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 33 / 33 |
| EER2 · BTU/Wh | 11.7–13 | 33 / 33 |
| HSPF2 · BTU/Wh | 7.8–8 | 33 / 33 |
| Cooling capacity · BTU/h | 27,400–29,400 | 33 / 33 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,400–30,600 | 33 / 33 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–18,200 | 33 / 33 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–14,000 | 33 / 33 |
| COP at 5°F / −15°C | 2–2.06 | 33 / 33 |
| Equipment / loop type | HP - Split System | 33 / 33 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 33 / 33 |
| Compressor staging | Single stage | 33 / 33 |
| Connected capability | No | 33 / 33 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FHMA5*42L*C*AHRI reference: 217683387 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4506009 → |
F5MA5*42L*C*AHRI reference: 217683388 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4506010 → |
FM(C,U)5Z36**AL*AHRI reference: 217683520 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506131 → |
FM(C,U)5Z30**AL*AHRI reference: 217683488 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506705 → |
FMA5X30**AL*AHRI reference: 217683616 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506721 → |
FMA5X36**AL*AHRI reference: 217683648 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506753 → |
FHMA5*30L*B*AHRI reference: 217683259 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4505659 → |
F5MA5*30L*B*AHRI reference: 217683260 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4505661 → |
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 217692243 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506767 → |
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 217693099 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506810 → |
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 217690841 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506834 → |
EA*5X37M21A*+ furnace: *92MSN1002120A*AHRI reference: 217690864 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506857 → |
EA*5X37M21A*+ furnace: *80CSU0802120B*AHRI reference: 217690013 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506870 → |
EA*5X37M21A*+ furnace: *80CSU0401712B*AHRI reference: 217689969 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4506893 → |
EA*5X37M21A*+ furnace: *92MSN1002122A*AHRI reference: 217690886 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506910 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 217690179 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506985 → |
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 217690204 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507010 → |
EA*5X43M21A*+ furnace: *80CSU0401712B*AHRI reference: 217691816 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4507017 → |
EA*5X43M21A*+ furnace: *80CSU0802120B*AHRI reference: 217691860 | 15.50 | 8.00 | 13900 | 2.04 | EPA 4507044 → |
EA*5X43M21A*+ furnace: *92MSN0802120A*AHRI reference: 217692737 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507066 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.