MARATHERM / AIR-SOURCE HEAT PUMP

R5H5S24*K*AAA*

15 SEER2 HP · source records, page 3

137 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for R5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 137 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5137 / 137
EER2 · BTU/Wh11.7–13137 / 137
HSPF2 · BTU/Wh7.8–8.5137 / 137
Cooling capacity · BTU/h22,200–24,400137 / 137
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000137 / 137
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200137 / 137
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900137 / 137
COP at 5°F / −15°C1.96–2.26137 / 137
Equipment / loop typeHP - Split System137 / 137
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)137 / 137
Compressor stagingSingle stage137 / 137
Connected capabilityNo137 / 137

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *97CMN0602120B*AHRI reference: 21420234415.507.80116002.12EPA 3406402
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 21420196815.507.80116002.14EPA 3406436
EA*5X37M21A*+ furnace: *97CMN0601714B*AHRI reference: 21420231715.507.80117002.12EPA 3406449
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 21420285415.507.80116002.14EPA 3406566
EA*5X37M17A*+ furnace: *80CSU0401712A*AHRI reference: 21419945515.507.80112002.08EPA 3406666
EA*5X37M21A*+ furnace: *80CSU1002120A*AHRI reference: 21420136015.507.80115002.12EPA 3406834
EA*5X37M21A*+ furnace: *96CTN0601714B*AHRI reference: 21420296215.507.80116002.12EPA 3406908
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21420133315.507.80113002.12EPA 3406931
EA*5X37M21A*+ furnace: *95CSU0601716B*AHRI reference: 21420215515.507.80116002.14EPA 3406973
EA*5X37M21A*+ furnace: *95CSU0802120B*AHRI reference: 21420218215.507.80116002.14EPA 3407025
EA*5X37M17A*+ furnace: *95CSU0601716B*AHRI reference: 21420044515.507.80113002.08EPA 3407035
EA*5X37M17A*+ furnace: *97CMN0801714B*AHRI reference: 21420055315.507.80113002.08EPA 3407050
EA*5X37M17A*+ furnace: *97CMN0601714B*AHRI reference: 21420052615.507.80114002.08EPA 3407120
EA*5X37M21A*+ furnace: *97CMN0801714B*AHRI reference: 21420237215.507.80116002.14EPA 3407360
EA*5X37M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21419984015.507.80113002.10EPA 3407403
EVD5X38M17A*+ furnace: *80MS(N,L)0451714A*AHRI reference: 21420730215.507.80115001.98EPA 3407429
EA*5X37M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21419980815.507.80113002.08EPA 3407549
EA*5X37M17A*+ furnace: *92MSN0601714A*AHRI reference: 21420070715.507.80113002.08EPA 3407676
EA*5X37M17A*+ furnace: *92MSN0801716A*AHRI reference: 21420073915.507.80113002.10EPA 3407752
EA*5X37M21A*+ furnace: OLV112A16AAHRI reference: 21420326115.507.80115002.10EPA 3407802

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →