MARATHERM / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 10

243 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 243 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18243 / 243
EER2 · BTU/Wh11.7–13.5243 / 243
HSPF2 · BTU/Wh7.8–8.5243 / 243
Cooling capacity · BTU/h45,500–50,500243 / 243
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500243 / 243
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600243 / 243
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600243 / 243
COP at 5°F / −15°C2.06–2.32243 / 243
Equipment / loop typeHP - Split System243 / 243
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)243 / 243
Compressor stagingTwo-stage243 / 243
Connected capabilityNo243 / 243

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 21563313716.008.10262002.20EPA 3953531
EA*5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 21563315116.008.10264002.16EPA 3953544
EA*5X61M24A*+ furnace: *96CTN1002122B*AHRI reference: 21563316516.008.10266002.16EPA 3953557
EA*5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 21563303216.008.10266002.16EPA 3953603
EA*5X61M24A*+ furnace: *95MSU1002120A*AHRI reference: 21563312116.008.10260002.20EPA 3953659
EA*5X61M24A*+ furnace: OLV154F20AAHRI reference: 21563326016.008.10260002.20EPA 3953744
ESH5X48M12A*+ furnace: *80CTL1102120B*AHRI reference: 21563349516.008.00248002.20EPA 3953836
ESH5X48M12A*+ furnace: *80CTL1352422B*AHRI reference: 21563350916.008.00248002.20EPA 3953849
ESH5X60M12A*+ furnace: *96CTN0802120B*AHRI reference: 21563454716.008.00252002.20EPA 3953945
ESH5X60M12A*+ furnace: *96CTN1002122B*AHRI reference: 21563456116.008.00252002.25EPA 3953964
ESH5X60M12A*+ furnace: *96CTN1202422B*AHRI reference: 21563457516.008.00254002.20EPA 3953977
ESH5X60M12A*+ furnace: *80MSU0601716A*AHRI reference: 21563410316.007.80252002.20EPA 3954024
ESH5X60M12A*+ furnace: *80MSU0802120A*AHRI reference: 21563412216.008.00248002.25EPA 3954109
ESH5X60M12A*+ furnace: *80CTL0702120B*AHRI reference: 21563418516.008.00254002.20EPA 3954144
ESH5X60M12A*+ furnace: *80CTL0902120B*AHRI reference: 21563419916.008.00252002.25EPA 3954164
ESH5X60M12A*+ furnace: *80CTL1102120B*AHRI reference: 21563421316.008.00252002.25EPA 3954176
ESH5X60M12A*+ furnace: *80CTL1352422B*AHRI reference: 21563422716.008.00250002.25EPA 3954188
ESH5X60M12A*+ furnace: *97CMN1202422B*AHRI reference: 21563439716.008.00254002.20EPA 3954259
EA*5X61M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572178116.008.00252002.26EPA 3981829
EA*5X61M21A*+ furnace: *80CSU1002120B*AHRI reference: 21572179516.008.00254002.25EPA 3981843

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.