MARATHERM / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 7

266 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 266 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5266 / 266
EER2 · BTU/Wh11.5–14266 / 266
HSPF2 · BTU/Wh7.8–8.5266 / 266
Cooling capacity · BTU/h22,200–25,000266 / 266
Heating capacity at 47°F / 8.3°C · BTU/h24,200–25,400266 / 266
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,000266 / 266
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500266 / 266
COP at 5°F / −15°C1.94–2.24266 / 266
Equipment / loop typeHP - Split System266 / 266
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)266 / 266
Compressor stagingTwo-stage266 / 266
Connected capabilityNo266 / 266

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M17A*+ furnace: OLV098A12*AHRI reference: 21564770017.008.10111002.08EPA 3960126 →
EA*5X37M17A*+ furnace: OMV098J12*AHRI reference: 21564772217.008.10111002.08EPA 3960140 →
EA*5X37M17A*+ furnace: OMV112K14AAHRI reference: 21564774217.008.10115002.04EPA 3960154 →
EA*5X37M17A*+ furnace: *95MSU0601716A*AHRI reference: 21564747817.007.80110002.10EPA 3960197 →
EA*5X37M17A*+ furnace: *95MSU0401712A*AHRI reference: 21564745117.007.80111002.08EPA 3960374 →
EA*5X37M21A*+ furnace: OLV098A12*AHRI reference: 21564877617.008.10115002.04EPA 3961744 →
ESH5X36M12A*+ furnace: *80CTL0701412B*AHRI reference: 21565205617.007.80110002.08EPA 3964064 →
ESH5X36M12A*+ furnace: *80CSU0401712A*AHRI reference: 21565176717.008.10111002.08EPA 3964497 →
ESH5X36M12A*+ furnace: *80MSU0802120A*AHRI reference: 21565198617.007.80110002.10EPA 3964755 →
ESH5X36M12A*+ furnace: *95MSU1002120A*AHRI reference: 21565277417.007.80110002.08EPA 3965069 →
ESH5X36M12A*+ furnace: *95MSU1002122A*AHRI reference: 21565279817.007.80110002.08EPA 3965081 →
EA*5X25M17A*+ furnace: *80CSU0401712B*AHRI reference: 21572042117.008.00110002.10EPA 3980236 →
EA*5X25M17A*+ furnace: *97CTN0601716A*AHRI reference: 21572044917.008.00111002.08EPA 3980368 →
EA*5X30M17A*+ furnace: *97CTN0801716A*AHRI reference: 21572055517.008.00110002.06EPA 3980920 →
EA*5X36M17A*+ furnace: *80CSU0401712B*AHRI reference: 21572060517.008.00109002.06EPA 3980969 →
EA*5X36M17A*+ furnace: *80CSU0601716B*AHRI reference: 21572061917.007.80109002.08EPA 3980992 →
EA*5X36M17A*+ furnace: *97CTN0801716A*AHRI reference: 21572064717.008.00110002.06EPA 3981012 →
EA*5X37M17A*+ furnace: *80CSU0401712B*AHRI reference: 21572069717.008.00110002.08EPA 3981202 →
EA*5X37M17A*+ furnace: *80CSU0601716B*AHRI reference: 21572071117.008.00110002.10EPA 3981221 →
EA*5X37M17A*+ furnace: *97CTN0601716A*AHRI reference: 21572072517.008.00111002.08EPA 3981299 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →