MARATHERM / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 13

266 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 266 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5266 / 266
EER2 · BTU/Wh11.5–14266 / 266
HSPF2 · BTU/Wh7.8–8.5266 / 266
Cooling capacity · BTU/h22,200–25,000266 / 266
Heating capacity at 47°F / 8.3°C · BTU/h24,200–25,400266 / 266
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,000266 / 266
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500266 / 266
COP at 5°F / −15°C1.94–2.24266 / 266
Equipment / loop typeHP - Split System266 / 266
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)266 / 266
Compressor stagingTwo-stage266 / 266
Connected capabilityNo266 / 266

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X24M12A*+ furnace: *80CTL0701716B*AHRI reference: 21564914716.008.00111002.05EPA 3997385 →
ESH5X24M12A*+ furnace: *80CTL0451712B*AHRI reference: 21564910716.008.00111002.05EPA 3997406 →
ESH5X30M12A*+ furnace: *97CMN0602120B*AHRI reference: 21565094816.008.00111002.05EPA 3997415 →
ESH5X24M12A*+ furnace: *80MSU0401712A*AHRI reference: 21564899516.007.80110002.05EPA 3997447 →
ESH5X30M12A*+ furnace: *97CTN0601716A*AHRI reference: 21571309416.008.00112002.05EPA 3997480 →
ESH5X30M12A*+ furnace: *97CMN0601714B*AHRI reference: 21565092616.008.00111002.05EPA 3997588 →
ESH5X30M12A*+ furnace: *95MSU0401712A*AHRI reference: 21565121016.008.00111002.05EPA 3997608 →
EA*5X30M14A*+ furnace: *96CTN0401410B*AHRI reference: 21564532016.008.00111002.00EPA 3997636 →
EA*5X36M17A*+ furnace: *97CTN0401410A*AHRI reference: 21799192916.008.00113002.02EPA 4566276 →
EA*5X37M17A*+ furnace: *97CTN0401410A*AHRI reference: 21799194316.008.00113002.04EPA 4566414 →
ESH5X30M12A*+ furnace: *96CTN0802120B*AHRI reference: 21565140315.507.80111002.06EPA 3719667 →
EA*5X25M17A*+TDRAHRI reference: 21564309915.507.80111001.96EPA 3956932 →
EA*5X37M21A*+TDRAHRI reference: 21564323815.507.80111001.94EPA 3956949 →
EA*5X24M14A*+ furnace: *96CTN0401410B*AHRI reference: 21564350715.507.80113002.00EPA 3957040 →
ESH5X30M12A*+ furnace: *80CSU0802120B*AHRI reference: 21572100615.507.80110002.08EPA 3980829 →
ESH5X30M12A*+ furnace: *97CTN0802120A*AHRI reference: 21572104815.507.80111002.06EPA 3980879 →
ESH5X30M12A*+ furnace: *97CTN1002122A*AHRI reference: 21572106215.507.80110002.08EPA 3981018 →
ESH5X30M12A*+ furnace: *97CTN1202422A*AHRI reference: 21572107615.507.80110002.06EPA 3981035 →
ESH5X24M12A*+ furnace: OMV112K14AAHRI reference: 21565027215.507.80115001.95EPA 3996918 →
ESH5X24M12A*+ furnace: *95CSU1002122B*AHRI reference: 21564944815.508.00111002.05EPA 3997283 →