MARATHERM / AIR-SOURCE HEAT PUMP

N5H5S24*K*AAA*

PERFORMANCE 16 SEER2 HP · source records, page 3

137 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for N5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 137 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5137 / 137
EER2 · BTU/Wh11.7–13137 / 137
HSPF2 · BTU/Wh7.8–8.5137 / 137
Cooling capacity · BTU/h22,200–24,400137 / 137
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000137 / 137
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200137 / 137
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900137 / 137
COP at 5°F / −15°C1.96–2.26137 / 137
Equipment / loop typeHP - Split System137 / 137
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)137 / 137
Compressor stagingSingle stage137 / 137
Connected capabilityNo137 / 137

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 21420196715.507.80116002.14EPA 3406435
EA*5X37M21A*+ furnace: *97CMN0601714B*AHRI reference: 21420231615.507.80117002.12EPA 3406446
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 21420285315.507.80116002.14EPA 3406564
EA*5X37M17A*+ furnace: *80CSU0401712A*AHRI reference: 21419945415.507.80112002.08EPA 3406665
EA*5X37M21A*+ furnace: *80CSU1002120A*AHRI reference: 21420135915.507.80115002.12EPA 3406832
EA*5X37M21A*+ furnace: *96CTN0601714B*AHRI reference: 21420296115.507.80116002.12EPA 3406907
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21420133215.507.80113002.12EPA 3406930
EA*5X37M21A*+ furnace: *95CSU0601716B*AHRI reference: 21420215415.507.80116002.14EPA 3406974
EA*5X37M21A*+ furnace: *95CSU0802120B*AHRI reference: 21420218115.507.80116002.14EPA 3407024
EA*5X37M17A*+ furnace: *95CSU0601716B*AHRI reference: 21420044415.507.80113002.08EPA 3407036
EA*5X37M17A*+ furnace: *97CMN0801714B*AHRI reference: 21420055215.507.80113002.08EPA 3407049
EA*5X37M17A*+ furnace: *97CMN0601714B*AHRI reference: 21420052515.507.80114002.08EPA 3407119
EA*5X37M21A*+ furnace: *97CMN0602120B*AHRI reference: 21420234315.507.80116002.12EPA 3407334
EA*5X37M21A*+ furnace: *97CMN0801714B*AHRI reference: 21420237115.507.80116002.14EPA 3407361
EA*5X37M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21419983915.507.80113002.10EPA 3407402
EVD5X38M17A*+ furnace: *80MS(N,L)0451714A*AHRI reference: 21420730115.507.80115001.98EPA 3407427
EA*5X37M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21419980715.507.80113002.08EPA 3407550
EA*5X37M17A*+ furnace: *92MSN0601714A*AHRI reference: 21420070615.507.80113002.08EPA 3407675
EA*5X37M17A*+ furnace: *92MSN0801716A*AHRI reference: 21420073815.507.80113002.10EPA 3407751
EA*5X37M21A*+ furnace: OLV112A16AAHRI reference: 21420326015.507.80115002.10EPA 3407795

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →