MAINLINE / AIR-SOURCE HEAT PUMP

MLP15AZ18AJ2N

Elite

12 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity17,100BTU/h

Each efficiency range summarizes published EPA records for MLP15AZ18AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 12 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1612 / 12
EER2 · BTU/Wh11.712 / 12
HSPF2 · BTU/Wh7.8–8.112 / 12
Cooling capacity · BTU/h17,10012 / 12
Heating capacity at 47°F / 8.3°C · BTU/h17,10012 / 12
Heating capacity at 17°F / −8.3°C · BTU/h11,300–12,10012 / 12
Heating capacity at 5°F / −15°C · BTU/h8,800–9,50012 / 12
COP at 5°F / −15°C2–2.112 / 12
Equipment / loop typeHP - Split System12 / 12
Refrigerant / source-reported GWPR-410A (GWP:2088)12 / 12
Compressor stagingTwo-stage12 / 12
Connected capabilityNo12 / 12

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MLH2VZ2417STANNCold climate designationAHRI reference: 21250788116.008.1092002.10EPA 3716084
MLH2CZ2417STANNAHRI reference: 21164166315.207.8092002.10EPA 2415046
TCFZ2417STANM+ furnace: ML97MV0603A17DHSAHRI reference: 21250786515.207.8090002.00EPA 3716087
TCFZ2417STANM+ furnace: ML98MV0603A17UPSAHRI reference: 21250786615.207.8088002.00EPA 3716092
TCFZ2417STANM+ furnace: ML97MV0703A17DHSAHRI reference: 21250786815.207.8090002.00EPA 3716093
TCFZ2417STANM+ furnace: ML98MV0703A17UPSAHRI reference: 21250786415.207.8091002.00EPA 3716095
TCFZ2417STANM+ furnace: ML962V0603A17M4SAHRI reference: 21250784015.207.8094002.10EPA 3716113
TCFZ2417STANM+ furnace: ML962V0703A17M4SCold climate designationAHRI reference: 21250785115.208.1093002.10EPA 3716122
TCFZ2417STANM+ furnace: ML962V0403A17M4SAHRI reference: 21250784115.207.8093002.10EPA 3716196
TCFZ2417STANM+ furnace: ML951V0603A17M4SAHRI reference: 21250781515.207.8094002.10EPA 3716197
TCFZ2417STANM+ furnace: ML951V0403A17M4SAHRI reference: 21250781215.207.8093002.10EPA 3716207
TCFZ2417STANM+ furnace: ML951V0403A17UHUAHRI reference: 21250781315.207.8095002.10EPA 3716231

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.