MAINLINE / AIR-SOURCE HEAT PUMP

ML30HP230LMNTH-O

ML Series

21 published source records · source checked Sep 21, 2026

SEER2 range15.3–17.5BTU/Wh
HSPF2 range9.3–10.8BTU/Wh
Cooling capacity29,000–30,000BTU/h

Each efficiency range summarizes published EPA records for ML30HP230LMNTH-O. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 21 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.3–17.521 / 21
EER2 · BTU/Wh10–1221 / 21
HSPF2 · BTU/Wh9.3–10.821 / 21
Cooling capacity · BTU/h29,000–30,00021 / 21
Heating capacity at 47°F / 8.3°C · BTU/h30,000–34,00021 / 21
Heating capacity at 17°F / −8.3°C · BTU/h23,200–25,00021 / 21
Heating capacity at 5°F / −15°C · BTU/h30,400–33,20021 / 21
COP at 5°F / −15°C1.8–221 / 21
Equipment / loop typeHP - Split System21 / 21
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)21 / 21
Compressor stagingContinuously variable21 / 21
Connected capabilityNo21 / 21

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ML30HP230WMAHU-I*Cold climate designationAHRI reference: 21760719817.5010.20320002.00EPA 4480762
ML30HP230WMAHU-ICold climate designationAHRI reference: 21662341417.5010.20320002.00EPA 4690961
ML30HP230G3AHU-I*Cold climate designationAHRI reference: 21760718417.2010.80332001.97EPA 4480706
ML36HP230G3AHU-I*Cold climate designationAHRI reference: 21760719017.2010.80332001.97EPA 4480711
ML36HP230G3AHU-ICold climate designationAHRI reference: 21662340617.2010.80332001.97EPA 4690967
ML30HP230G3AHU-ICold climate designationAHRI reference: 21662340017.2010.80332001.97EPA 4690973
ML36HP230LMNTAHU-I*Cold climate designationAHRI reference: 21760722216.8010.00326001.96EPA 4480722
ML30HP230LMNTAHU-I*Cold climate designationAHRI reference: 21760717516.8010.00326001.96EPA 4480758
ML30HP230LMNTAHU-ICold climate designationAHRI reference: 21586431216.8010.00326001.96EPA 4690920
ML36HP230LMNTAHU-ICold climate designationAHRI reference: 21662344216.8010.00326001.96EPA 4690938
ML30HP230PCAHU-I*Cold climate designationAHRI reference: 21760720416.309.50310001.86EPA 4480714
ML30HP230PCAHU-ICold climate designationAHRI reference: 21662342116.309.50310001.86EPA 4690955
ML36HP230CC21-I*Cold climate designationAHRI reference: 21760721516.009.60320001.85EPA 4480717
ML36HP230CC17-I*Cold climate designationAHRI reference: 21760721316.009.60320001.85EPA 4480764
ML36HP230CC21-ICold climate designationAHRI reference: 21662343416.009.60320001.85EPA 4690944
ML36HP230CC17-ICold climate designationAHRI reference: 21662343216.009.60320001.85EPA 4690946
ML36HP230UC17-ICold climate designationAHRI reference: 21789034416.009.60320001.85EPA 4691521
ML36HP230UC21-ICold climate designationAHRI reference: 21789034616.009.60320001.85EPA 4691522
ML36HP230CC14-I*Cold climate designationAHRI reference: 21760721215.309.30304001.80EPA 4480715
ML36HP230CC14-ICold climate designationAHRI reference: 21662343115.309.30304001.80EPA 4690947