MAINLINE / AIR-SOURCE HEAT PUMP

ML30HP230LMNTH-O

ML Series

21 published source records · source checked Sep 21, 2026

SEER2 range15.3–17.5BTU/Wh
HSPF2 range9.3–10.8BTU/Wh
Cooling capacity29,000–30,000BTU/h

Each efficiency range summarizes published EPA records for ML30HP230LMNTH-O. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 21 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.3–17.521 / 21
EER2 · BTU/Wh10–1221 / 21
HSPF2 · BTU/Wh9.3–10.821 / 21
Cooling capacity · BTU/h29,000–30,00021 / 21
Heating capacity at 47°F / 8.3°C · BTU/h30,000–34,00021 / 21
Heating capacity at 17°F / −8.3°C · BTU/h23,200–25,00021 / 21
Heating capacity at 5°F / −15°C · BTU/h30,400–33,20021 / 21
COP at 5°F / −15°C1.8–221 / 21
Equipment / loop typeHP - Split System21 / 21
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)21 / 21
Compressor stagingContinuously variable21 / 21
Connected capabilityNo21 / 21

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ML30HP230WMAHU-I*Cold climate designationAHRI reference: 21760719817.5010.20320002.00EPA 4480762 →
ML30HP230WMAHU-ICold climate designationAHRI reference: 21662341417.5010.20320002.00EPA 4690961 →
ML30HP230G3AHU-I*Cold climate designationAHRI reference: 21760718417.2010.80332001.97EPA 4480706 →
ML36HP230G3AHU-I*Cold climate designationAHRI reference: 21760719017.2010.80332001.97EPA 4480711 →
ML36HP230G3AHU-ICold climate designationAHRI reference: 21662340617.2010.80332001.97EPA 4690967 →
ML30HP230G3AHU-ICold climate designationAHRI reference: 21662340017.2010.80332001.97EPA 4690973 →
ML36HP230LMNTAHU-I*Cold climate designationAHRI reference: 21760722216.8010.00326001.96EPA 4480722 →
ML30HP230LMNTAHU-I*Cold climate designationAHRI reference: 21760717516.8010.00326001.96EPA 4480758 →
ML30HP230LMNTAHU-ICold climate designationAHRI reference: 21586431216.8010.00326001.96EPA 4690920 →
ML36HP230LMNTAHU-ICold climate designationAHRI reference: 21662344216.8010.00326001.96EPA 4690938 →
ML30HP230PCAHU-I*Cold climate designationAHRI reference: 21760720416.309.50310001.86EPA 4480714 →
ML30HP230PCAHU-ICold climate designationAHRI reference: 21662342116.309.50310001.86EPA 4690955 →
ML36HP230CC21-I*Cold climate designationAHRI reference: 21760721516.009.60320001.85EPA 4480717 →
ML36HP230CC17-I*Cold climate designationAHRI reference: 21760721316.009.60320001.85EPA 4480764 →
ML36HP230CC21-ICold climate designationAHRI reference: 21662343416.009.60320001.85EPA 4690944 →
ML36HP230CC17-ICold climate designationAHRI reference: 21662343216.009.60320001.85EPA 4690946 →
ML36HP230UC17-ICold climate designationAHRI reference: 21789034416.009.60320001.85EPA 4691521 →
ML36HP230UC21-ICold climate designationAHRI reference: 21789034616.009.60320001.85EPA 4691522 →
ML36HP230CC14-I*Cold climate designationAHRI reference: 21760721215.309.30304001.80EPA 4480715 →
ML36HP230CC14-ICold climate designationAHRI reference: 21662343115.309.30304001.80EPA 4690947 →