Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–19 | 192 / 192 |
| EER2 · BTU/Wh | 10–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 9–9.5 | 192 / 192 |
| Cooling capacity · BTU/h | 23,000–35,600 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000–35,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,600–31,400 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,000–33,600 | 192 / 192 |
| COP at 5°F / −15°C | 2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | No | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36C5ADS1+CC+ furnace: TPLC080C16MP13Cold climate designationAHRI reference: 218026902 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4577627 → |
CTM36C5ADS1+CC+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 218026897 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4577632 → |
CTM36C5ADS1+CC+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 218026892 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4577637 → |
CTM36C5ADS1+CC+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 218026887 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4577642 → |
CTM36C5ADS1+CC+ furnace: Z9VT100C20SMPC1AHRI reference: 218026883 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4577646 → |
CTM36C5ADS2+JMC16C2SN1+CCCold climate designationAHRI reference: 218588195 | 18.00 | 9.00 | 32200 | 2.00 | EPA 4649871 → |
CTF36C5ADS2+CC+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 218588038 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4649923 → |
CTM36B5ADS2+CC+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 218588033 | 18.00 | 9.50 | 33600 | 2.00 | EPA 4649925 → |
CTM36B5ADS2+CC+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 218588021 | 18.00 | 9.50 | 33600 | 2.00 | EPA 4649929 → |
CTM36B5ADS2+CC+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 218588009 | 18.00 | 9.50 | 33600 | 2.00 | EPA 4649933 → |
CTF36C5ADS2+CC+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 218587997 | 18.00 | 9.50 | 32400 | 2.00 | EPA 4649937 → |
CTF36C5ADS2+CC+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 218587985 | 18.00 | 9.50 | 32400 | 2.00 | EPA 4649941 → |
CTM36C5ADS2+CC+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 218587973 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4649945 → |
CTF36C5ADS2+CC+ furnace: LP9C100C16MP13Cold climate designationAHRI reference: 218587806 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650003 → |
CTF36C5ADS2+CC+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 218587793 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650007 → |
CTF36C5ADS2+CC+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 218587781 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650011 → |
CTF36C5ADS2+CC+ furnace: LP9C080C16MP13Cold climate designationAHRI reference: 218587776 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650013 → |
CTF36C5ADS2+CC+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 218587760 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650017 → |
CTF36C5ADS2+CC+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 218587749 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650021 → |
CTM36B5ADS2+CC+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 218587736 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650025 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →