XH936E2C11
LX SERIES · source records, page 3
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH936E2C11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–19 | 192 / 192 |
| EER2 · BTU/Wh | 10–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 9–9.5 | 192 / 192 |
| Cooling capacity · BTU/h | 23,000–35,600 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000–35,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,600–31,400 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,000–33,600 | 192 / 192 |
| COP at 5°F / −15°C | 2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | No | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM30B5ACS2+CC+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 218587540 | 19.00 | 9.00 | 24600 | 2.00 | EPA 4650093 → |
CTF30B5ACS2+CC+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 218587529 | 19.00 | 9.00 | 24600 | 2.00 | EPA 4650097 → |
CTF36B5ADS2+JMC12B2SN1+CCCold climate designationAHRI reference: 218587275 | 19.00 | 9.00 | 32200 | 2.00 | EPA 4650197 → |
CTM30B5ACS2+CC+ furnace: LP9C060B12MP13Cold climate designationAHRI reference: 218587266 | 19.00 | 9.00 | 24600 | 2.00 | EPA 4650201 → |
CTM30B5ACS2+CC+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 218587248 | 19.00 | 9.00 | 24600 | 2.00 | EPA 4650210 → |
CTM30B5ACS2+CC+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 218587233 | 19.00 | 9.00 | 24600 | 2.00 | EPA 4650218 → |
CTF30B5ACS2+CC+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 218587225 | 19.00 | 9.00 | 24600 | 2.00 | EPA 4650221 → |
CTF30B5ACS2+CC+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 218587210 | 19.00 | 9.00 | 24600 | 2.00 | EPA 4650229 → |
CTF30B5ACS2+CC+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 218587193 | 19.00 | 9.00 | 24600 | 2.00 | EPA 4650238 → |
CTM30B5ACS2+CC+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 218586976 | 19.00 | 9.00 | 24400 | 2.00 | EPA 4650345 → |
CTF30B5ACS2+CC+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 218586961 | 19.00 | 9.00 | 24400 | 2.00 | EPA 4650353 → |
CTF30B5ACS2+JMC12B2SN1+CCCold climate designationAHRI reference: 218586945 | 19.00 | 9.00 | 24200 | 2.00 | EPA 4650361 → |
CTM36B5ADS1+CC+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 218027700 | 18.00 | 9.50 | 33600 | 2.00 | EPA 4570219 → |
CTM36B5ADS1+CC+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 218027695 | 18.00 | 9.50 | 33600 | 2.00 | EPA 4570224 → |
CTM36B5ADS1+CC+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 218027690 | 18.00 | 9.50 | 33600 | 2.00 | EPA 4570229 → |
CTF36C5ADS1+CC+ furnace: LP9C100C16MP13Cold climate designationAHRI reference: 218027550 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4570236 → |
CTF36C5ADS1+CC+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 218027545 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4570241 → |
CTF36C5ADS1+CC+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 218027540 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4570246 → |
CTF36C5ADS1+CC+ furnace: LP9C080C16MP13Cold climate designationAHRI reference: 218027538 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4570248 → |
CTF36C5ADS1+CC+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 218027533 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4570253 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →