XH936E2C11
LX SERIES · source records, page 10
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH936E2C11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–19 | 192 / 192 |
| EER2 · BTU/Wh | 10–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 9–9.5 | 192 / 192 |
| Cooling capacity · BTU/h | 23,000–35,600 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000–35,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,600–31,400 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,000–33,600 | 192 / 192 |
| COP at 5°F / −15°C | 2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | No | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36B5ADS1+CC+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 218027330 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4570287 → |
CTF36B5ADS1+CC+ furnace: LPLC080B12MP13Cold climate designationAHRI reference: 218027676 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4577335 → |
CTF36B5ADS1+CC+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 218027671 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4577340 → |
CTM36B5ADS1+CC+ furnace: LPLC080B12MP13Cold climate designationAHRI reference: 218027340 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4577442 → |
CTM36B5ADS1+CC+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 218027335 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4577447 → |
CTF36B5ADS2+CC+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 218587962 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4649949 → |
CTM36B5ADS2+CC+ furnace: LP9C060B12MP13Cold climate designationAHRI reference: 218587523 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4650099 → |
CTM36B5ADS2+CC+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 218587511 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4650103 → |
CTM36B5ADS2+CC+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 218587500 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4650107 → |
CTM36B5ADS2+CC+ furnace: LPLC080B12MP13Cold climate designationAHRI reference: 218587433 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4650129 → |
CTM36B5ADS2+CC+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 218587420 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4650133 → |
CTM36B5ADS2+CC+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 218587408 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4650137 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →