Luxaire / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES · source records, page 4

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21701972916.008.10270002.36EPA 4014805 →
CTM60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21701973016.008.10270002.36EPA 4014806 →
CTU60D5XGS1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 21701973116.008.10274002.28EPA 4014807 →
CTF60D5CGS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21701973216.008.10274002.28EPA 4014808 →
CTU60C5XGS1+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21701973316.008.10272002.24EPA 4014809 →
CTF60C5CGS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21701973416.008.10272002.24EPA 4014810 →
CTF60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21701973516.008.10274002.32EPA 4014811 →
CTM60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21701973616.008.10274002.32EPA 4014812 →
CTF60C5CGS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701973816.008.10274002.26EPA 4014813 →
CTU60C5XGS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21701973716.008.10274002.26EPA 4014814 →
CTF60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701973916.008.10272002.34EPA 4014815 →
CTM60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701974016.008.10272002.34EPA 4014816 →
CTM60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21701974116.008.10270002.36EPA 4014817 →
CTU60C5XGS1+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 21701974216.008.10272002.26EPA 4014818 →
CTF60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21701974316.008.10272002.26EPA 4014819 →
CTF60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21701974416.008.10274002.34EPA 4014820 →
CTF60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21701974516.008.10274002.34EPA 4014821 →
CTF60C5CGS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21701974716.008.10276002.26EPA 4014822 →
CTM60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21701974616.008.10268002.34EPA 4014823 →
CTU60C5XGS1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21701974816.008.10276002.26EPA 4014824 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →