XH648E2S11
LX SERIES · source records, page 25
554 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 554 / 554 |
| EER2 · BTU/Wh | 11.7–12 | 554 / 554 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 554 / 554 |
| Cooling capacity · BTU/h | 45,000–49,000 | 554 / 554 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 554 / 554 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 554 / 554 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 554 / 554 |
| COP at 5°F / −15°C | 2–2.4 | 554 / 554 |
| Equipment / loop type | HP - Split System | 554 / 554 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 554 / 554 |
| Compressor staging | Two-stage | 554 / 554 |
| Connected capability | No | 554 / 554 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60C5XGS1+TXV+ furnace: TM9V100C20MP12AHRI reference: 217994118 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571005 → |
CTF60C5CGS1+ furnace: LP9C100C20MP13AHRI reference: 217994116 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571007 → |
CTF60C5CGS1+ furnace: TP9C100C20MP13AHRI reference: 217994111 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571012 → |
CTF60C5CGS1+ furnace: TM9V100C20MP12AHRI reference: 217994106 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571017 → |
CTM60C5CGS1+ furnace: LP9C100C16MP13AHRI reference: 217994104 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571019 → |
CTM60C5CGS1+ furnace: TP9C100C16MP13AHRI reference: 217994099 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571024 → |
CTM60C5CGS1+ furnace: TM9V100C16MP12AHRI reference: 217994094 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571029 → |
CTM60C5CGS1+ furnace: LP9C080C16MP13AHRI reference: 217994092 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571031 → |
CTM60C5CGS1+ furnace: TP9C080C16MP13AHRI reference: 217994087 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571036 → |
CTM60C5CGS1+ furnace: TM9V080C16MP12AHRI reference: 217994082 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571041 → |
CTU60C5XGS1+TXV+ furnace: LP9C080C16MP13AHRI reference: 217994080 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571043 → |
CTU60C5XGS1+TXV+ furnace: TP9C080C16MP13AHRI reference: 217994075 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571048 → |
CTU60C5XGS1+TXV+ furnace: TM9V080C16MP12AHRI reference: 217994070 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571053 → |
CTF60C5CGS1+ furnace: LP9C080C16MP13AHRI reference: 217994068 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571055 → |
CTF60C5CGS1+ furnace: TP9C080C16MP13AHRI reference: 217994063 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571060 → |
CTF60C5CGS1+ furnace: TM9V080C16MP12AHRI reference: 217994058 | 15.20 | 8.00 | 26000 | 2.00 | EPA 4571065 → |
CTM60D5CGS1+ furnace: Z9ES120D20SMPS1AHRI reference: 217022657 | 15.20 | 8.10 | 27600 | 2.24 | EPA 4571220 → |
CTM60C5CGS1+ furnace: Z9ES100C16SMPS1AHRI reference: 217022619 | 15.20 | 8.10 | 27200 | 2.24 | EPA 4571221 → |
CTM60C5CHS1AHRI reference: 217019828 | 15.20 | 7.80 | 27800 | 2.26 | EPA 4571378 → |
CTF60D5CHS1AHRI reference: 217019795 | 15.20 | 7.80 | 27800 | 2.26 | EPA 4571379 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →