Luxaire / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 8

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17496 / 496
EER2 · BTU/Wh11–12496 / 496
HSPF2 · BTU/Wh8–8.5496 / 496
Cooling capacity · BTU/h32,800–36,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800496 / 496
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800496 / 496
COP at 5°F / −15°C2–2.5496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21701812816.008.10187002.32EPA 4013386
CTM48C5CFS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21701813016.008.10192002.40EPA 4013388
CTM48C5CFS1+JMVT17CC2N1AHRI reference: 21701813416.008.50189002.48EPA 4013390
CTM48C5CFS1+JMC17C2SN1AHRI reference: 21701813616.008.50189002.48EPA 4013391
CTM36C5CDS1+JME16C2SN1AHRI reference: 21701813816.008.10184002.36EPA 4013392
CTM36C5CDS1+JMC16C2SN1AHRI reference: 21701814016.008.10185002.38EPA 4013393
CTM36C5CDS1+JMVT16CC2N1AHRI reference: 21701814216.008.10185002.38EPA 4013394
CTM48C5CFS1+JMET16CS2N1AHRI reference: 21701814416.008.10190002.46EPA 4013395
CTM48D5CFS1+JMC20D2SN1AHRI reference: 21701814616.008.50190002.48EPA 4013396
CTM36C5CDS1+JMET12CS2N1AHRI reference: 21701814816.008.10184002.36EPA 4013397
CTM36C5CDS1+JMC17C2SN1AHRI reference: 21701815016.008.50189002.36EPA 4013398
CTM48C5CFS1+JMVT16CC2N1AHRI reference: 21701815216.008.50189002.48EPA 4013399
CTM36C5CDS1+JME12C2SN1AHRI reference: 21701815616.008.10188002.38EPA 4013402
CTM48C5CFS1+JME12C2SN1AHRI reference: 21701815816.008.50190002.46EPA 4013404
CTM48D5CFS1+JMVT20DC2N1AHRI reference: 21701816016.008.50192002.48EPA 4013406
CTM36C5CDS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21701816416.008.10186002.34EPA 4013409
CTM48C5CFS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21701816616.008.50195002.42EPA 4013411
CTM48C5CFS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701816816.008.50190002.46EPA 4013413
CTM36C5CDS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701817016.008.10185002.36EPA 4013415
CTM36C5CDS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21701817216.008.10188002.34EPA 4013417

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →