Luxaire / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 5

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17496 / 496
EER2 · BTU/Wh11–12496 / 496
HSPF2 · BTU/Wh8–8.5496 / 496
Cooling capacity · BTU/h32,800–36,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800496 / 496
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800496 / 496
COP at 5°F / −15°C2–2.5496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS2+JMC17C2SN1AHRI reference: 21852778017.008.50191002.46EPA 4646412
CTU48C5XFS2+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 21852777617.008.10192002.40EPA 4646416
CTF48C5CFS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21852777217.008.10192002.40EPA 4646420
CTF48D5CFS2+JMC20D2SN1AHRI reference: 21852803217.008.50191002.50EPA 4647866
CTF48D5CFS2+JMVT20DC2N1AHRI reference: 21852802817.008.50191002.50EPA 4647870
CTU48C5XFS2+JME12C2SN2+TXVAHRI reference: 21863811617.008.50193002.44EPA 4664487
CTF48C5CFS2+JME12C2SN2AHRI reference: 21863811017.008.50193002.44EPA 4664493
CTU48C5XFS2+JME16C2SN2+TXVAHRI reference: 21863810417.008.10190002.44EPA 4664499
CTF48C5CFS2+JME16C2SN2AHRI reference: 21863809817.008.10190002.44EPA 4664505
CTF36C5CDS1+JMC16C2SN1AHRI reference: 21701710016.008.50188002.40EPA 4012788
CTF36C5CDS1+JMVT17CC2N1AHRI reference: 21701710216.008.50188002.38EPA 4012790
CTF36C5CDS1+JME12C2SN1AHRI reference: 21701711016.008.10188002.38EPA 4012797
CTF36C5CDS1+JMET16CS2N1AHRI reference: 21701712416.008.10184002.36EPA 4012809
CTF36B5CDS1+JME12B2SN1AHRI reference: 21701712616.008.10186002.36EPA 4012811
CTU36B5XDS1+JME12B2SN1+TXVAHRI reference: 21701712816.008.10186002.36EPA 4012813
CTF36C5CDS1+JMC17C2SN1AHRI reference: 21701713016.008.50188002.38EPA 4012815
CTF36C5CDS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21701714416.008.10196002.26EPA 4012827
CTF36C5CDS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21701714816.008.10186002.32EPA 4012830
CTF36B5CDS1+ furnace: Z8ES100B12LMPS1AHRI reference: 21701722816.008.10187002.32EPA 4012834
CTF36B5CDS1+ furnace: Z8ES080B12LMPS1AHRI reference: 21701721816.008.10186002.32EPA 4012837