Luxaire / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 24

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17496 / 496
EER2 · BTU/Wh11–12496 / 496
HSPF2 · BTU/Wh8–8.5496 / 496
Cooling capacity · BTU/h32,800–36,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800496 / 496
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800496 / 496
COP at 5°F / −15°C2–2.5496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS2+ furnace: TP9C100C16MP13AHRI reference: 21852732415.208.10180002.00EPA 4646856 →
CTM36C5CDS2+ furnace: TM9V100C16MP12AHRI reference: 21852732015.208.10180002.00EPA 4646860 →
CTU36B5XDS2+TXV+ furnace: LP9C060B12MP13AHRI reference: 21852731815.208.10180002.00EPA 4646862 →
CTU36B5XDS2+TXV+ furnace: TP9C060B12MP13AHRI reference: 21852731415.208.10180002.00EPA 4646866 →
CTU36B5XDS2+TXV+ furnace: TM9V060B12MP12AHRI reference: 21852731015.208.10180002.00EPA 4646870 →
CTF36B5CDS2+ furnace: LP9C060B12MP13AHRI reference: 21852730815.208.10180002.00EPA 4646872 →
CTF36B5CDS2+ furnace: TP9C060B12MP13AHRI reference: 21852730415.208.10180002.00EPA 4646876 →
CTU36B5XDS2+TXV+ furnace: TP9C080B12MP13AHRI reference: 21852729415.208.10180002.00EPA 4646880 →
CTU36B5XDS2+TXV+ furnace: TM9V080B12MP12AHRI reference: 21852729015.208.10180002.00EPA 4646884 →
CTF36B5CDS2+ furnace: LP9C080B12MP13AHRI reference: 21852728815.208.10180002.00EPA 4646886 →
CTF36B5CDS2+ furnace: TP9C080B12MP13AHRI reference: 21852728415.208.10180002.00EPA 4646890 →
CTF36B5CDS2+ furnace: TM9V080B12MP12AHRI reference: 21852728015.208.10180002.00EPA 4646894 →
CTF36B5CDS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852724815.208.10186002.28EPA 4646904 →
CTU36B5XDS2+TXV+ furnace: Z9ET080B12SMPS1AHRI reference: 21852724415.208.10187002.30EPA 4646908 →
CTF36B5CDS2+ furnace: Z9ET080B12SMPS1AHRI reference: 21852724015.208.10187002.30EPA 4646912 →
CTU36B5XDS2+TXV+ furnace: Z9ET060B12SMPS1AHRI reference: 21852721215.208.10184002.28EPA 4646940 →
CTF36B5CDS2+ furnace: Z9ET060B12SMPS1AHRI reference: 21852720815.208.10184002.28EPA 4646944 →
CTM36B5CDS2+ furnace: LP9C060B12MP13AHRI reference: 21852812615.208.10180002.00EPA 4647772 →
CTM36B5CDS2+ furnace: TP9C060B12MP13AHRI reference: 21852812215.208.10180002.00EPA 4647776 →
CTM36B5CDS2+ furnace: TM9V060B12MP12AHRI reference: 21852811815.208.10180002.00EPA 4647780 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →