XH636E2S11
LX SERIES · source records, page 21
496 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 496 / 496 |
| EER2 · BTU/Wh | 11–12 | 496 / 496 |
| HSPF2 · BTU/Wh | 8–8.5 | 496 / 496 |
| Cooling capacity · BTU/h | 32,800–36,000 | 496 / 496 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 496 / 496 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,000–23,800 | 496 / 496 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,600–19,800 | 496 / 496 |
| COP at 5°F / −15°C | 2–2.5 | 496 / 496 |
| Equipment / loop type | HP - Split System | 496 / 496 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 496 / 496 |
| Compressor staging | Two-stage | 496 / 496 |
| Connected capability | No | 496 / 496 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36C5CDS1+ furnace: TM9V100C16MP12AHRI reference: 217993938 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4514948 → |
CTM36C5CDS1+ furnace: LP9C100C16MP13AHRI reference: 217993936 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4514949 → |
CTF36C5CDS1+ furnace: TP9C100C16MP13AHRI reference: 217993943 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4514954 → |
CTF36C5CDS1+ furnace: LP9C100C16MP13AHRI reference: 217993948 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4514960 → |
CTU36B5XDS1+TXV+ furnace: TP9C060B12MP13AHRI reference: 217993907 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4514982 → |
CTF36C5CDS1+ furnace: LP9C100C20MP13AHRI reference: 217993844 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4515049 → |
CTM36C5CDS1+ furnace: TM9V100C20MP12AHRI reference: 217993847 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4515052 → |
CTM36C5CDS1+ furnace: TP9C100C20MP13AHRI reference: 217993862 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4515061 → |
CTM36C5CDS1+ furnace: LP9C100C20MP13AHRI reference: 217993879 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4515067 → |
CTF36B5CDS1+ furnace: TM9V060B12MP12AHRI reference: 217993884 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4515069 → |
CTF36B5CDS1+ furnace: TP9C060B12MP13AHRI reference: 217993895 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4515076 → |
CTF36B5CDS1+ furnace: LP9C060B12MP13AHRI reference: 217993900 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4515081 → |
CTU36B5XDS1+TXV+ furnace: TM9V060B12MP12AHRI reference: 217993902 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4515082 → |
CTM48C5CFS1AHRI reference: 217019613 | 15.20 | 8.10 | 19800 | 2.32 | EPA 4571411 → |
CTM48D5CFS1AHRI reference: 217019612 | 15.20 | 8.10 | 19800 | 2.32 | EPA 4571412 → |
CTM36B5CDS1+ furnace: Z9ES080B12SMPS1AHRI reference: 217018213 | 15.20 | 8.10 | 18700 | 2.28 | EPA 4571730 → |
CTM36B5CDS1+ furnace: Z9ES060B12SMPS1AHRI reference: 217018211 | 15.20 | 8.10 | 18900 | 2.26 | EPA 4571731 → |
CTM36B5CDS1+ furnace: Z8ES100B12LMPS1AHRI reference: 217018209 | 15.20 | 8.10 | 18300 | 2.32 | EPA 4571732 → |
CTM36B5CDS1+ furnace: Z8ES080B12LMPS1AHRI reference: 217018197 | 15.20 | 8.10 | 18600 | 2.30 | EPA 4571733 → |
CTM36B5CDS1+ furnace: Z8ES080B12SMPS1AHRI reference: 217018177 | 15.20 | 8.10 | 18600 | 2.30 | EPA 4571734 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →