Luxaire / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 10

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17496 / 496
EER2 · BTU/Wh11–12496 / 496
HSPF2 · BTU/Wh8–8.5496 / 496
Cooling capacity · BTU/h32,800–36,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800496 / 496
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800496 / 496
COP at 5°F / −15°C2–2.5496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21701822316.008.10191002.28EPA 4013486
CTM36C5CDS1+ furnace: Z9ES080C20SMPS1AHRI reference: 21701822516.008.10189002.32EPA 4013487
JHC36B5CD2SS1AHRI reference: 21701960616.008.10189002.32EPA 4013705
JHC42C5CF2SS1AHRI reference: 21701960716.008.10189002.48EPA 4013706
JHE36C5CD2SS1AHRI reference: 21701960816.008.10185002.36EPA 4013707
JHC36C5CD2SS1AHRI reference: 21701960916.008.10186002.42EPA 4013708
JHE42C5CF2SS1AHRI reference: 21701961116.008.10190002.46EPA 4013709
CTM48C5CFS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21719800116.008.10191002.46EPA 4014050
CTF48C5CFS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21719800216.008.10192002.44EPA 4014051
CTF48C5CFS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21719800916.008.10191002.46EPA 4014052
CTU48C5XFS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21719800316.008.10192002.44EPA 4014053
CTM48C5CFS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21719800416.008.10191002.46EPA 4014054
CTF48C5CFS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21719800516.008.10192002.44EPA 4014055
CTU48C5XFS1+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 21719800616.008.10192002.44EPA 4014056
CTM48C5CFS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21719800716.008.10192002.44EPA 4014057
CTF36C5CDS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21719800816.008.10186002.38EPA 4014058
CTU48C5XFS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21719801016.008.10191002.46EPA 4014059
CTF48C5CFS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21719801116.008.10192002.44EPA 4014060
CTU48C5XFS1+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 21719801216.008.10192002.44EPA 4014061
CTM48C5CFS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21719801316.008.10191002.46EPA 4014062

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →