XH560E2S11
LX SERIES
42 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH560E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 42 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 42 / 42 |
| EER2 · BTU/Wh | 11–11.7 | 42 / 42 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 42 / 42 |
| Cooling capacity · BTU/h | 54,500–56,500 | 42 / 42 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 55,500–57,000 | 42 / 42 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,400–39,000 | 42 / 42 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–32,400 | 42 / 42 |
| COP at 5°F / −15°C | 2.1–2.38 | 42 / 42 |
| Equipment / loop type | HP - Split System | 42 / 42 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 42 / 42 |
| Compressor staging | Two-stage | 42 / 42 |
| Connected capability | No | 42 / 42 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
JHE60D5CH2SS1AHRI reference: 214424724 | 15.20 | 7.80 | 29800 | 2.10 | EPA 3627821 → |
CTM60D5CJS1+JMC20D2SN1AHRI reference: 214425502 | 15.20 | 8.10 | 31400 | 2.34 | EPA 4498946 → |
CTM60D5CJS1+JMVT20DC2N1AHRI reference: 214425512 | 15.20 | 8.10 | 31400 | 2.34 | EPA 4498951 → |
CTF60D5CHS1+JMET18DS2N1AHRI reference: 214429345 | 15.20 | 7.80 | 32200 | 2.30 | EPA 4570778 → |
CTM60D5CHS1+JME18D2SN1AHRI reference: 214429227 | 15.20 | 7.80 | 31600 | 2.30 | EPA 4570783 → |
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 214428894 | 15.20 | 7.80 | 31800 | 2.30 | EPA 4570798 → |
JHC60C5CH2SS1AHRI reference: 214428884 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4570803 → |
CTM60D5CHS1+JMVT20DC2N1AHRI reference: 214426684 | 15.20 | 7.80 | 31800 | 2.30 | EPA 4570816 → |
CTM60D5CJS1+JME18D2SN1AHRI reference: 214425521 | 15.20 | 8.10 | 31600 | 2.38 | EPA 4570841 → |
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217444961 | 15.20 | 7.80 | 32400 | 2.28 | EPA 4571144 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217444960 | 15.20 | 7.80 | 32400 | 2.28 | EPA 4571145 → |
CTU60D5XHS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 216783725 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4572197 → |
CTF60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 216783710 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4572202 → |
CTM60C5CHS1+ furnace: Z8ES100C20LMPS1AHRI reference: 216782986 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4572217 → |
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 214809128 | 15.20 | 7.80 | 31600 | 2.30 | EPA 4572257 → |
CTU60D5XHS1+JMC20D2SN1+TXVAHRI reference: 214809123 | 15.20 | 7.80 | 31800 | 2.30 | EPA 4572262 → |
CTU60D5XHS1+JMVT20DC2N1+TXVAHRI reference: 214809118 | 15.20 | 7.80 | 31800 | 2.30 | EPA 4572267 → |
CTU60D5XHS1+JMET18DS2N1+TXVAHRI reference: 214809113 | 15.20 | 7.80 | 32200 | 2.30 | EPA 4572272 → |
CTU60D5XHS1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 214650131 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4572317 → |
CTF60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 214605465 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4572364 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →