Luxaire / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 10

364 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 364 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16364 / 364
EER2 · BTU/Wh11–12364 / 364
HSPF2 · BTU/Wh7.8–8.1364 / 364
Cooling capacity · BTU/h44,500–48,000364 / 364
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000364 / 364
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400364 / 364
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200364 / 364
COP at 5°F / −15°C2.1–2.42364 / 364
Equipment / loop typeHP - Split System364 / 364
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)364 / 364
Compressor stagingTwo-stage364 / 364
Connected capabilityNo364 / 364

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60D5XHS1+TXV+ furnace: TP9C120D20MP13AHRI reference: 21464997315.207.80268002.34EPA 4572324 →
CTU60D5XHS1+TXV+ furnace: TM9V120D20MP12AHRI reference: 21464995715.207.80268002.34EPA 4572329 →
CTU60D5XGS1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 21464985215.207.80254002.24EPA 4572334 →
CTF60C5CGS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460587015.207.80258002.20EPA 4572339 →
CTM60C5CGS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460586515.207.80258002.26EPA 4572344 →
CTF60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21460586015.207.80254002.24EPA 4572349 →
CTM60D5CGS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21460577515.207.80256002.28EPA 4572354 →
CTM60C5CGS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460568515.207.80260002.26EPA 4572359 →
CTM60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21460545515.207.80256002.28EPA 4572366 →
CTM60C5CGS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21460545015.207.80258002.26EPA 4572369 →
CTF60D5CGS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21460542515.207.80254002.24EPA 4572374 →
CTM60C5CGS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21460540515.207.80258002.26EPA 4572379 →
CTF60C5CHS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21460526515.207.80268002.30EPA 4572389 →
CTM60C5CHS1+ furnace: Z9ES100C20SMPS1AHRI reference: 21460525015.208.00264002.36EPA 4572394 →
CTF60C5CHS1+ furnace: Z9ES100C20SMPS1AHRI reference: 21460524515.207.80270002.30EPA 4572399 →
CTM60C5CHS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21460524015.207.80262002.34EPA 4572404 →
CTF60C5CHS1+ furnace: Z9ES100C16SMPS1AHRI reference: 21460523015.207.80266002.32EPA 4572409 →
CTM60C5CHS1+ furnace: LP9C100C20MP13AHRI reference: 21442885015.207.80270002.30EPA 4572423 →
CTM60C5CHS1+ furnace: TP9C100C20MP13AHRI reference: 21442884515.207.80270002.30EPA 4572428 →
CTM60C5CHS1+ furnace: TM9V100C20MP12AHRI reference: 21442884015.207.80270002.30EPA 4572433 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →