Luxaire / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 5

275 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16275 / 275
EER2 · BTU/Wh10–12275 / 275
HSPF2 · BTU/Wh7.8–8.1275 / 275
Cooling capacity · BTU/h32,400–35,000275 / 275
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800275 / 275
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000275 / 275
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400275 / 275
COP at 5°F / −15°C2–2.44275 / 275
Equipment / loop typeHP - Split System275 / 275
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)275 / 275
Compressor stagingTwo-stage275 / 275
Connected capabilityNo275 / 275

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48C5CFS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21643778715.208.10179002.40EPA 3815031
CTM48D5CFS1+JME18D2SN1AHRI reference: 21643779215.208.10176002.42EPA 3815036
CTM48C5CFS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21643780215.208.10180002.38EPA 3815041
CTM48C5CFS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21643781215.208.10180002.38EPA 3815046
CTM48C5CFS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21643781715.208.10181002.38EPA 3815051
CTM36C5CDS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744492015.208.10184002.40EPA 4045059
CTM36C5CDS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744492115.208.10184002.40EPA 4045060
CTF36C5CDS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744492215.208.10184002.40EPA 4045061
CTF36C5CDS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744492315.208.10184002.40EPA 4045062
CTM48C5CFS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744493115.208.10177002.42EPA 4045068
CTF48C5CFS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744493215.208.10178002.40EPA 4045070
CTM48C5CFS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744493015.208.10178002.40EPA 4045071
CTU48C5XFS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21744493315.208.10178002.40EPA 4045072
CTU48C5XFS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21744493515.208.10177002.42EPA 4045073
CTF48C5CFS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744493415.208.10177002.42EPA 4045074
CTF36C5CDS1+JMET12CS2N1AHRI reference: 21443155415.208.10176002.00EPA 4046803
CTM48C5CFS1+ furnace: TM8V120C20MP12AHRI reference: 21443133315.208.10180002.00EPA 4046805
CTM48C5CFS1+ furnace: TM8V100C20MP12AHRI reference: 21443133815.208.10180002.00EPA 4046810
CTM48C5CFS1+ furnace: TMLV120C20MP12AHRI reference: 21443134315.208.10180002.00EPA 4046815
CTM48C5CFS1+ furnace: TP9C100C16MP13AHRI reference: 21443137915.208.10180002.00EPA 4046823

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.